Laserfiche WebLink
tIIsI:P Worldwide <br /> Fire Protection Contacts www.tyco-fire.com <br /> Products <br /> Series TY-FRB, 5.6 K-factor <br /> Upright, Pendent, and Recessed Pendent Sprinklers <br /> Quick Response, Standard Coverage <br /> General NOTICE „ , , <br /> The TYCO Series TY-FRB Sprinklers <br /> Description described herein must be installed and <br /> maintained in compliance with this doc- o , ., <br /> The TYCO Series TY-FRB, 5.6 K-factor, ument, as well as with the applicable <br /> Upright (TY313) and Pendent (TY323) standards of the National Fire Protec 4` _, <br /> Sprinklers described in this data sheet tion Association,in addition to the stan- ` " <br /> are quick response,standard coverage, dards of any other authorities having <br /> decorative 3 mm glass bulb-type spray jurisdiction. Failure to do so may impair <br /> sprinklers designed for use in light or the performance of these devices. <br /> ordinary hazard,commercial occupan -:..--,-.:----r ': <br /> cies such as banks, hotels, and shop- The owner is responsible for maintain- <br /> ping <br /> aintain ping malls. ing their fire protection system and "' <br /> devices in proper operating condition. <br /> The recessed version of the Series TY- The installing contractor or sprinkler <br /> FRB Pendent Sprinkler,where applica- manufacturer should be contacted with _- <br /> ble, is intended for use in areas with a any questions. <br /> finished ceiling.This recessed pendent <br /> sprinkler uses one of the following: <br /> Sprinkler <br /> • A two-piece Style 15 Recessed �" �, <br /> Escutcheon with recessed adjust- , <br /> ment up to 5/8 inch (15,9 mm) rom Identification ` 11 <br /> the flush pendent position. Number (SIN) <br /> • A two-piece Style 20 Recessed <br /> Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2"NPT <br /> ment up to 1/2 inch (12,7 mm) from TY323 Pendent 5.6K, 1/2"NPT <br /> the flush pendent position. _ gip" <br /> The adjustment provided by the Technical <br /> Recessed Escutcheon reduces the Temperature Rating <br /> accuracy to which the fixed pipe drops Data 135°F(57°C) <br /> to the sprinklers must be cut. 155°F(68°C) <br /> Intermediate level versions of Series Approvals 175°F(79°C) <br /> UL and C-UL Listed 200°F(93°C) <br /> TY-FRB Sprinklers are described in FM, LPCB, and VdS Approved <br /> 286°F(141°C) <br /> Technical Data Sheet TFP357. Sprin- pP <br /> kler guards and shields are described CE Certified Finishes <br /> in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler: Refer to Table A <br /> and C-UL Listed as Corrosion-Resis- Recessed Escutcheon: White Coated, <br /> tant Sprinklers. Chrome Plated, or Brass Plated <br /> Maximum Working Pressure Physical Characteristics <br /> 175 psi (12.1 bar) Frame Bronze <br /> 250 psi (17.2 bar)* Button Brass/Copper <br /> *The maximum working pressure of 250 psi Sealing Assembly Stainless <br /> IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON <br /> Always refer to Technical Data derwriters Laboratories,Inc.(UL). Bulb Glass <br /> Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze <br /> WARNING"that provides cautions K=5.6 GPM/psitt2(80,6 LPM/barti2) Deflector Bronze <br /> with respect to handling and instal- <br /> lation of sprinkler systems and com- <br /> ponents. Improper handling and <br /> installation can permanently dam- <br /> age a sprinkler system or its compo- <br /> nents and cause the sprinkler to fail <br /> to operate in a fire situation or cause <br /> it to operate prematurely. <br /> Page 1 of 4 FEBRUARY 2014 TFP172 <br />