Laserfiche WebLink
,A <br /> � �� <br /> •R <br /> �: <br /> i�. <br /> :ti <br /> 600 J 4 = 150 galions ' <br /> Calculate Drainback <br /> Total pipe Length: ?30 feet <br /> Liquid Volume of Pipe: 17. 43 gallons per 100 feet <br /> Drainback {gal) = Length tft) 1 'Jolume (ga1;l00ft) <br /> 0 gal = 230 ft x 1i.43 gal/100ft <br /> • Total Pumpout = Dose + Drainback <br /> 150 gal = 150 gal + 0 gal <br /> 5. Volume for Alarm using 3 inch Depth <br /> 60 gal = 3 inches x 20 gal <br /> 6. Recommended Calculate Reserve Capacity (75$ of Daily Flow) <br /> 450 gal = .75 x 600 gal <br /> 7. Calculated Total Gallons <br /> 672 gal = 12 + 150 + 60 + 45U <br /> Pumping Rate: 39.96 qpm <br /> Calculated Timer ON Setting: <br /> Total Minutes ON per Day = Dose Gallons divided by gpm <br /> 3.75 minutes = 150 gal / 39.96 qpm <br /> Minutes on per pose = 15 for 4 total doses <br /> Calculated Timer OFF Setting <br /> Minutes OFF Setting <br /> 1428 min. OFF per day = 1440 min/day - 1� min ON/day <br /> Minutes OFF between doses: 357 <br /> c <br />