My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info including older design
Orono
>
Property Files
>
Street Address
>
S
>
Sixth Avenue North
>
1940 Sixth Ave N - 27-118-23-42-0003
>
Septic
>
septic info including older design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:21:57 PM
Creation date
1/16/2019 12:36:59 PM
Metadata
Fields
Template:
x Address Old
House Number
1940
Street Name
6th
Street Type
Avenue
Street Direction
North
Address
1940 6th Avenue North
Document Type
Septic
PIN
2711823420003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� o� <br /> o.:�,, _ o . <br /> ���'�T� CITY of �RQNO � <br /> � � ����� <br /> �`1���a�;j� � <br /> '�� �`4i fj-^+��r G'� biunlcipal Oflices -. <br /> l �'�:�ts�`�g,�y ' Street Address: Ma1inY�ddreuc <br /> .��u <br /> H� 2750 Kelley Parfcway P.O. Bax 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323•0065 <br /> � 9sa-�yq-y600 <br /> To Current Owner: Address: I 9 y� ��X-�� ��t� � � <br /> City Ordinance 199 requires that each existin�on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewa�e treatrnent system at the above address has been inspected and appeazs to fall into the categories checked below. <br /> SYST'EM CONFORMITY (1-3): � <br /> 1 "CODE SYSTEM"An ISTS which meets all the location,duign and construction standards of the current Orono Municipal Code. <br /> 2 "CO�LIANT SYSTEM" An ISTS which dou not rrteet all the location.design and construction standards of the current Orono biunicipat <br /> Code but doa meet the three foot separation nquirement or two foot requirement for rystems installed 1996 or earlier.and which is not failino or <br /> 'en imminent threat W public health or safety. <br /> 3O "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a daignated 100-yeu Saod plain,any ISTS which may <br /> or may not meet ali the location,design,or conswction standards of We current Orono Municipal Code and which is failing for any reason;and <br /> any ISTS with less than three feet of unsaturaud soil or sand between the distribution device and the timidng soil characteristiu. <br /> TANK CO�JDIT'ION(�-:71: 6 p. <br /> Tank inspection indicates: � . <br /> �Pumpout not needed at this time. � <br /> Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. <br /> Tank was last pumped `1 S ). <br /> rtake sure seatic tanl:s are pumaed throuo_h manhole and not through white insoection pipes <br /> This allo�ys for the proner cleanin� <br /> 7 Inspection risers missin�tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. <br /> INFIELD CONDITION(8-1�: � <br /> Dninfield is dry,no surfacino evident. <br /> 9 Some evidence of surfacing�not critical yet , � � <br /> 10 Drainfield is saturated and visibly dischazgin,untreated efflaent to the surface. Contact the Ciry Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> C01�1�i SENTS: �c�:��.<�c c�.; S s�a�- (�MP I.�,�a- ��� �.�Sr �5c C�P��<<� by <br /> ��t.=��.to► o . p,:.s c�FS �.. s�& �.� M�k c��c�. <br /> 10 - � -va-- ��u / <br /> Date of Insptction Matt Bolterman- Septic System Insptctor <br /> Note: In the evrnt that this inspection rcpoR ts used w satisfy the nquirements for a moctgage or other�ansfer ofproperry.be adviscd that this rcpaR daa not gu�3.'�:ee <br /> or certify�4at an extsdng rystem wiil continue to tunction properly.b ut is rr.ereiy an op inion of the adequary of the systcm under current conditions based on the availsble <br /> inCormation. <br />
The URL can be used to link to this page
Your browser does not support the video tag.