My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2006-P10079 - new septic
Orono
>
Property Files
>
Street Address
>
S
>
Sixth Avenue North
>
1805 Sixth Ave N - 27-118-23-41-0002/4
>
Septic
>
2006-P10079 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:21:35 PM
Creation date
1/16/2019 11:17:42 AM
Metadata
Fields
Template:
x Address Old
House Number
1805
Street Name
6th
Street Type
Avenue
Street Direction
North
Address
1805 6th Avenue North
Document Type
Septic
PIN
2711823410002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
University of Minnesota Pump Selection Procedure - 10/25/04 <br /> ' All�boxed rectangles must be entered,the rest will be calculated. <br /> oNsr,�e <br /> 1. Detenrdne pump capacity: T�TM� <br /> A. Gravity Distribution P�"'W <br /> 1.Minimum required discharge is 10 gpm <br /> 2.Ma�dmum suggested discharge is 45 gpm <br /> For other establishments at least 10°�6 greater than the water � <br /> supply rate,but no faster than the rate at which effluent will flow <br /> out of the distribution device. <br /> B. Pressure Distribution-see pressure design wo�ksheet �ou f`�ar'^e"r Svs'�'' <br /> &pdnt of discharge <br /> Selected Pump Capacity: �gpm fotoi�pe <br /> length <br /> 2A.elevatlon <br /> inlet ` difference <br /> 2. Determine Total Dynamic Head(TDH) wpe�;;�m - '; <br /> , <br /> A. Elewation difference beri�een pump and pant of discharge. '�' ' <br /> OfeetI;:� __ _ ; -------------------------- ------ <br /> B. Special head requirement?(See F'�gure-Special Head Requirements) <br /> �5 feet Special Head Requi�ernents <br /> Gravity Distribution OPt <br /> C. Fric�a�loss in supply pipe Pressure Distribution 5ft <br /> 1. Seled pipe diameter �2 in <br /> 2. Enter Figure E-9 with gpm(1A or B)and pipe diameter(C1) <br /> Read friction loss in feet r 100 feet from Figure E-9 E-9 Friction Loss in Plastic Pipe <br /> Friction bss= 3.28 ft/100 ft of pipe 100 R <br /> naninal <br /> 3.Determine total pipe length from pump discharge to soil system discharge point Flow Rate �i e diameter <br /> Estimate by�ding 25 perc;ent to pipe�ngth for fiction loss in fittings. m 1.5' 2.0' 3" <br /> � �,, <br /> Pi times 1.25=equivalent pipe length � �;� , L��= <br /> 315 ft x 1.25= 393.75 feet 25 3.73 1.11 016 <br /> ��` ��, . �� ��. <br /> 4.Calculate total friction loss by mul6plying friction loss(C2j 35 6.96 2.06 0.3 <br /> by the equivalent pipe length(C3)and divide by 1�. 4a $,.� . r�S4. 0:39 <br /> Fricbon Loss= 3.28 ft/100ft X 393.75 ft I 100= 12.9 feet 45 11.07 3.28 0.48 <br /> 50 13�46 ;3�9 �;58: <br /> D. Total head requirement is the sum of elevation difference(A),special 55 4.76 0.7 <br /> head requirements(B),and total friction loss(C4). 60 S.8 '.0.82 <br /> 22 R + 5 ft + 13.0 ft 65 6.48 0.95 <br /> 70 7.44' 1.09 <br /> Total Head: 40.0 feet <br /> 3. Pump Selection <br /> 1.A pump must be selected to deliver at least 44 gpm(1A o�B) <br /> with at least 40.0 feet of total head(2D). <br /> I hereby certify that I have completed this wo�C in accordance with all applicable ordinances,rules and laws. <br /> (signature) 810 (�icense#) 3/�/0(� Date <br /> Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.