Re: Henn Co on plans - 1998
Orono
>
Property Files
>
Street Address
>
S
>
Sixth Avenue North
>
0725 Sixth Ave N - 26-118-23-44-0006 Spring Hill Golf
>
Correspondence
>
Re: Henn Co on plans - 1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:19:26 PM
Creation date
1/9/2019 10:25:12 AM
Metadata
Fields
Template:
x Address Old
House Number
725
Street Name
6th
Street Type
Avenue
Street Direction
North
Address
725 6th Avenue North
Document Type
Correspondence
PIN
2611823440006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Page 2 October 2, 1998 <br /> 4. �II there be a grease trap and where will it be located? Check with the local <br /> muniapality for their regulations. If a grease trap is installed, the lid should be <br /> mounted flush with the floor and it shall be acxessible for cleaning. <br /> Sinks <br /> 1. Either adequate space or a shield must be provided befinreen the hand sink and <br /> preparation table/storage shelving to predude contamination by splash. <br /> 2. Ensure hand cleanser, single-use towels, and a fingemail brush are provided at the <br /> hand wash sink located in the food/bar service area. <br /> 3. The plans and specification did not depict a utility service sink. Ensure a mop sink is <br /> provided in the facility for proper disposal of mop water. , <br /> 4. Where will cleaning produds and equipment be stored? Provide hooks or hang-up <br /> brackets at the utility sink storage of mops and brooms. <br /> Storage <br /> 1. Adequate approved NSF or equivalent shelving covering the food senrice operation <br /> must be provided to ensure that food products, utensils, or single service artides are <br /> stored at least six inches off the floor. <br /> 2. Provide an area for storage of employees' personal belongings that is separate form <br /> food, dean equipment,and single service supplies. <br /> Installations <br /> 1. All annular openings around pipes and other conduits where they pass through the <br /> walls and floor must be sealed(caulked). . <br /> 2. All junctures between the wall surFace and the edges of attached equipment must be <br /> sealed with approved caulk/sealing compound (e.g. three-compartment sink, hand <br /> sink, etc.). <br /> 3. If conduit pipes are provided for the beverage lines they must extend at least three to <br /> four inches above the finished floor elevation at both ends and the annular opening <br /> befinreen the beverage lines and the conduit pipe sealed with a hard material and <br /> provided with a cleanable finish. <br /> Room Finishes <br /> 1. Provide a finish schedule for walls, ceilings, and floors for the kitchen, bar, storage <br /> areas,and bathrooms. <br /> 2. Toilet rooms must be provided with seff-closing doors, adequate ventilation, hand <br /> cleanser, single use towels or hand drying devices, fissue paper and waste paper <br /> receptacles. Toilet rooms used be women shall have at teast one covered waste <br /> receptade. <br /> 3. All doors to the outside of the establishment must be self-closing and vermin proof. <br />