My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
project manual-salt storage bldg-2002
Orono
>
Property Files
>
Street Address
>
S
>
Shoreline Drive
>
3880 Shoreline Drive - 17-117-23-33-0151
>
Misc
>
project manual-salt storage bldg-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:37:07 PM
Creation date
12/18/2018 2:17:38 PM
Metadata
Fields
Template:
x Address Old
House Number
3880
Street Name
Shoreline
Street Type
Drive
Address
3880 Shoreline Drive
Document Type
Misc
PIN
1711723330151
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
241
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> � SECTION 16050 ' <br /> � <br /> BASIC MATERIALS AND METHODS <br /> i <br /> � Y.00 GENERAL ' <br /> � <br /> � A. Unless noted otherwise in this Specification or on the Drawings, all materials <br /> shall be new and in their original packages. All materials shall comply with this ' <br /> Specification and at a minimum all applicable codes and standards as listed in <br /> Section 16010. , <br /> � B. Provide nameplates on all equipment such as disconnects, starters, MCC's, panels <br /> and switchgear. Nameplates shall identify equipment by name and source of ' <br /> '� power. They shall be a minimum of 1 1/4" x 3", or larger if necessary for <br /> i wording. L,ettering shall be a minimum of 3/16" in height. Identify all pull and <br /> junction boxes with circuit or feeder numbers and source of power using black ' <br /> magic marlcer. <br /> � C. All distribution equipment, such as disconnects, starters, MCC's, panels and ' <br /> 1 switchgear, shall be obtained from one manufacturer. <br /> D. Each panelboard shall be provided with a typed circuit directory. Clearly describe , <br /> � loads and areas served. Room names or Owner's room numbers shall be used. <br /> i Handwritten directories will not be accepted. ' <br /> � <br /> t <br /> E. The Contractor shall perform saw cutting, trenching, backfilling, compaction and <br /> i patching required for underground raceway systems shown or specified. , <br /> 1 <br /> � F. The Contractor shall provide concrete pads for all floor mounted equipment. Pads <br /> ! shall be 4" thick and extend a minimum of 2" beyond equipment. ' <br /> f <br /> G. Any cutting and patching required in walls, floors, ceilings or partitions for the <br /> installation of electrical systems shall be the responsibility of the Electrical ' <br /> { Contractor. All cutting and patching shall be done with the prior approval of the <br /> � Architectl Engineer. Patching to match existing finishes shall be performed by <br /> , the proper trades such as concrete finishers, sheetrockers, tapers, painters etc. at ' <br /> `': the expense of the Electrical Contractor. <br /> H. The Contractor shall be responsible for verifying locations of such things as , <br /> i piping, ductwork, equipment, door swings, heights of cabinets and counters, etc., <br /> jprior to the installation of all electrical equipment. Installed electrical work that � <br /> interferes with the work of other trades shall be relocated by the Electrical <br /> ' <br /> Contractor at no additional cost to the Owner. <br /> I. Contractor shall verif� the location of all fixtures and devices with the Architect � <br /> prior to installation. <br /> , <br /> 022101 LG <br /> F102 3/14/02 ' <br /> 16050 - 1 <br /> ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.