My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
project manual-salt storage bldg-2002
Orono
>
Property Files
>
Street Address
>
S
>
Shoreline Drive
>
3880 Shoreline Drive - 17-117-23-33-0151
>
Misc
>
project manual-salt storage bldg-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:37:07 PM
Creation date
12/18/2018 2:17:38 PM
Metadata
Fields
Template:
x Address Old
House Number
3880
Street Name
Shoreline
Street Type
Drive
Address
3880 Shoreline Drive
Document Type
Misc
PIN
1711723330151
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
241
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DIVISION 03 Section 3450 - Architectunl Precast Concrete-Plant Cast , <br /> 3.03 ERECTTON AND LOCATION TOLERANCES , <br /> A. Install azchitectural precast concrete units level,plumb,squaze,and true,without exceeding <br /> the recommended erection and location tolerances of MNL-117. ' <br /> B. Erection Tolerances:Install azchitectural precast concrete units so that each unit after <br /> erection mmplies with following dimensional requirements. ' <br /> 1. Concave or convex bowing of any part of a flat surface not to exceed length of <br /> bow/360,with a maximum of 1 inch(25 mm) and up to 30 feet(9 m). <br /> 2. Maximum warpage of 1 corner out of plane of other 3,the greater of 1/16 inch ' <br /> (1.6 mm)per 12-inch(300 mm)distance from nearest adjacent corner. <br /> C. Tolerances for location of Architectural Precast Units:Fabricate and erect azchitectural ' <br /> precast concrete units so that joints between units do not exceed the following alignment for <br /> exterior units is outside face. <br /> 1. Face width of joints: Plus or minus 1/4 inch(6 mm). ' <br /> 2. Joint taper: l/40 inch per 12-inch length(1:480),with maximum length of taper over 10 <br /> feet(3 m)of 1/4 inch(6 mm)> <br /> 3. Step in face: l/4 inch(6 mm). , <br /> 4. Jog in alignment of edges: l/4 inch(6 mm). <br /> 5. Jog in alignment of reveals 1/4 inch(6 mm). <br /> 6. Plumb in any 10 feet(3 m)of element height: l/4 inch(6 mm). ' <br /> 7. Variation from level:Plus or minus 1/2 inch(13 mm)in any 40-foot(12-rn)run. <br /> 3.04 REPAIRS ' <br /> A. Repair exposed exterior surfaces of architectural precast concrete units to match color, <br /> texture,and uniformity of surrounding concrete when permitted by Architect. <br /> B. Remove and replace damaged azchitectural precast concrete units when repairs do not meet ' <br /> requirements. <br /> 3.05 CLEANIlVG , <br /> A. Qean exposed surfaces of architectural precast concrebe units after erection to remove <br /> weld marks,other markings,dirt,and stains. ' <br /> 1. Wash and rinse according to azchitectural precast concrete fabricators recommendations. <br /> Protect other work from staining or damage due to cleaning operations. , <br /> 2. Do not use cleaning materials or processes that could change the appeazance of exposed <br /> architectural precast concrete finishes. <br /> END OF SECTION 03450 ' <br /> , <br /> , <br /> i <br /> 03450- 10 <br /> HENNEPIN COUNTY �rono Salt Stora�e , <br /> March 22,2002 Project No.:0031569 Contract No.:O�S 1R2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.