2016-00232 - plumbing
Orono
>
Property Files
>
Street Address
>
S
>
Shoreline Drive
>
3596 Shoreline Drive - 17-117-23-43-0107
>
Permits/Inspections
>
2016-00232 - plumbing
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:42:46 PM
Creation date
12/12/2018 2:45:34 PM
Metadata
Fields
Template:
x Address Old
House Number
3596
Street Name
Shoreline
Street Type
Drive
Address
3596 Shoreline Drive
Document Type
Permits/Inspections
PIN
1711723430107
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ii't <br /> 1 ' <br /> 443 Lafayette Road N. i M�N N ESt�TA �EPA�'2TM�NT {JF (651)284-5005 <br /> St. Paul, Minnesota 55155 7 ��5�� � �= i������ 1-800-342-5354 <br /> www.dli.mn.gov f N <br /> � <br /> Division of Construction Codes and Licensing <br /> REPORT ON PLANS <br /> Plans and specifications on plumbing: Woofington Remodel, 3596 Shoreline Dr, Orono, Hennepin County, <br /> Minnesota, Plan No. PLB 1601-00134 <br /> OWNERSHIP: Woof Diversified, 2829 Spy Glass Dr, Chaska, MN 55318 <br /> SUBMITTER: Terwisscha Construction, 1550 Willmar Avenue SE, Will�s�,,�,41 <br /> �� ��:r Ce�t�� <br /> Compti��ce C�_ <br /> Plans Dated: January 8, 2016 � �f E�rono <br /> �� �a�'� Da�e <br /> Date Received: January 20, 2016 ��� ` <br /> Revi��r � <br /> Date Approved: February 4,2016 <br /> SCOPE: This review is limited to the provisions of the Minnesota Plumbing Code, as amended. The review is <br /> based upon the supposition that the data on which the design is based are correct. Approval is contingent upon <br /> requirements included in this report. A copy of the approved plans,specifications, and this Report on Plans <br /> must be retained at the project location for future reference. <br /> INSPECTIONS: All plumbing installations must be tested and inspected in accordance with the requirements of <br /> the Minnesota Plumbing Code. No plumbing work may be covered prior to completing the required tests and <br /> inspections. The contractor/installer must obtain an inspection permit from the Minnesota Department of Labor <br /> and Industry when an installation is for a state owned facility, Minnesota Department of Health licensed <br /> healthcare facility, or a project in an area where there is no local administrative authority. To schedule <br /> inspections, contact the state plumbing standards representative for your region. For your regional inspector's <br /> contact information, visit our website at http://www.dli.mn.gov/CCLD/CCLDContactus.asp <br /> REQUIREMENT(S): <br /> 1. The specified hand-held sprayer for a domestic kitchen sink faucet(S-1) is not approved for installation in a <br /> commercial type setting. The two sinks would require the installation of pressure vacuum breakers or <br /> reduced pressure zone backflow preventers on each water supply branch to each fixture(see Minnesota <br /> Rules, part 4715.2000). <br /> 2. Pet wash tubs with water inlets below the spill line or with hand-held sprayers must have approved high- <br /> hazard backflow preventers on each fixture branch(see Minnesota Rules,part 4715.2100). This would <br /> require the installation of pressure vacuum breakers or reduced pressure zone backflow preventers on each <br /> water supply branch. <br /> 3. The water supply line to the automatic clothes washer must be protected against backflow by the use of an <br /> air gap or approved vacuum breaker. The discharge must be through an air break(see Minnesota Rules, <br /> part 4715.1230). <br /> 4. Water supply connections to fixtures or equipment which have inlets below the spill line must be provided <br /> with an air gap ar approved backflow preventer(see Minnesota Rules,part 4715.2000). This shall include <br /> the potable water connection to the autoclave. / <br /> rU � 0 �l e� �"d�' t� �i ��1 <br /> Cm� � �` �' t S <br /> � � ���� � <br /> s s �° <br /> � b <br /> This information can be provided to you in alternative formats(Braille,large print or audio). <br /> An Equal Opportunity Employer <br />
The URL can be used to link to this page
Your browser does not support the video tag.