FlRE PROTECTION SYSTEMS <br /> snd Air inlets and exhausts shall be located so as to prevent snow materials in fire protection-rated frames, the area <br /> t be or ice blockage. of which shall not exceed that tested. The doors � <br /> na- �F�909.4.6 Duration of operation.All portions of active or shall be close-fitting within operational tolerances <br /> � passive smoke control systems shall be capable of continued and shall not have undercuts, louvers or grilles. <br /> �res � operation after detection of the fire event for a period of not The doors shall have head and jamb stops, astra- <br /> trol less than either 20 minutes or LS times the calculated egress gals or rabbets at meeting edges and shall be auto- <br /> ��or- time, whichever is less. matio-closing by smoke detection in accordance <br /> �e witt► Section 715.4.73. Positive-latching devices <br /> �gi- �F�909.5 Smoke barrier construction.Smoke barriers shall are not required. <br /> nts � ,;omP1Y�'ith Section 709, and shall be constructed and sealed � <br /> el �� limit leakage areas exclusive of protected openings. The 4• Group I-3. <br /> Y <br /> Per i�aximum allowable leakage area shall be the aggregate area 5. Openings between smoke zones with clear ceiling <br /> ,u_ �alculated using the following leakage area ratios: heights of 14 feet (4267 mm) or greater and <br /> �nd l. Walls: A/A,�,=0.00100 bank-down capacity of greater than 20 minutes as <br /> determined by the design fire size. <br /> di- � 2• Exit enclosures: A/fl,ti,=0.00035 [F] 909.5.2.1 Ducts and air transfer openings. Ducts <br /> ch � and air transfer openings are required to be protected <br /> �o � 3. All other shafts: A/fl,ti,=0.00150 with a minimum Class II,250°F(121°C)smoke damper <br /> 09 ` complying with Section 716. <br /> i fy 4. Floors and roofs: A/AF=0.00050 [F] 909.6 Pressurization method. The primary mechanical <br /> its means of controlling smoke shall be by pressure differences <br /> iy- where: across smoke barriers. Maintenance of a tenable environment <br /> �es A = Total leakage area, square feet(m�). is not required in the smoke control zone of fire origin. <br /> �c- <br /> ce AF = Unit floor or roof area of barrier, square feet(mz). [F]909.61 Minimum pressure difference.The minimum <br /> pressure difference across a smoke barrier shall be <br /> �- A,�. = Unit wall area of barrier,square feet(m�). 0.05-inch water gage (0.0124 kPa) in fully sprinklered <br /> g The leakage area ratios shown do not include openings due buildings. <br /> c- <br /> io doars, operable windows or similar gaps. These shall be In buildings permitted to be other than fully sprinklered, <br /> of included in calculating the total leakage area. the smoke control system shall be designed to achieve pres- <br /> a_ [F]909.5.1 Leakage area.The total leakage area of the bar- sure differences at least two times the maximum calculated <br /> �_ rier is the product of the smoke barrier gross area multiplied pressure difference produced by the design fire. <br /> �n ; by the allowable leakage area ratio, plus the area of other <br /> � openings such as gaps and operable windows. Compliance �F] 909.6.2 Maximum pressure difference. The maxi- <br /> ls mum air pressure difference across a smoke barrier shall be <br /> shall be determined by achieving the minimum air pressure <br /> difference across the barrier with the system in the smoke determined by required door-opening or closing forces.The <br /> ,h control mode for mechanical smoke control systems. Pas- actual force required to open exit doors when the system is <br /> �t sive smoke control systems tested using other approved in the smoke control mode shall be in accordance with Sec- <br /> n Imeans such as door fan testing shall be as approved by the tion 1008.1.2. Opening and closing forces for other doors <br /> fire code official. shall be determined by standard engineering methods for <br /> �e the resolution of forces and reactions.The calculated force <br /> [F]909.5.2 Opening protection.Openings in smoke barri- to set a side-hinged,swinging door in motion shall be deter- <br /> ers shall be protected by automatic-closing devices actuated mined by: <br /> d by the required controls for the mechanical smoke control <br />'' System. Door openings shall be protected by fire door F=Fd�+K(WA�P)/2(W-c� (Equation9-1) <br />� assemblies complying with Section 715.43. where: <br /> Exceptions: <br /> A = Door area,square feet(mz). <br /> e 1. Passive smoke control systems with auto- <br /> _ matic-closing devices actuated by spot-type d = Distance from door handle to latch edge of door, <br /> � smoke detectors listed for releasing service feet(m). <br /> installed in accordance with Section 907.10. F = Total door opening force,pounds(N). <br />, 2. Fixed openings between smoke zones that are pro- Fd�. = Force required to overcome closing device,pounds <br />� tected utiliaing the airflow method. �N�. <br />; 3. In Group I-2,where such doors are installed across K = Coefficient 5.2(1.0). <br /> corridors,a pair of opposite-swinging doors with- <br /> � � out a center mullion shall be installed having W = Door width,feet(m). <br /> vision panels with fire protection-rated glazing �p = Design pressure difference. inches of water(Pa). <br /> �s�NTERNATIONAL BUILDING CODE� 191 <br />