Laserfiche WebLink
�€ `'�" <br /> VIKING AUTOMATIC SPRINKLER COMPANY � � <br /> ,�;. <br /> �, �� 1301 L'ORIENT STREET • ST. PAUL, MINNESOTA 551 17 • (612) SSK-33(x) • I-800-229-6263 • FAX: (612) SSK-3310 �-.�' <br />� '�'! <br /> t.r:-, SHEET 2 OF 2 - Use separate sheet for each system inspection System No. or Description if multiple a <br />������' ��� systems t;, <br />� ,�; Inspection Report , � <br /> ' No. ' <br /> � '� <br /> ,f�� � F si <br />� 11. Date dry-pipe valve trip tested (control valve partially open) r A ' � '� (See Trip Test Table which fo/lows) , i' 4� <br /> 12. Date dry-pine valve trip tested (control valve fully open) (See Trip Test Table which follows) ,=; <br />¢ �,r� 13. Date quick-opening device tested (See Trip Test Table which follows) -� � <br />�� DRY VALVE TRIP TEST TABLE �.0.0. { � <br /> � MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. rs <br /> ;-r� � <br /> r ` � <br /> " DRY PIPE Time to Trip Water Air Trip Point Time Water Reached Alarm Operated <br /> OPERATING Thru Test Pipe Pressure pressure Air Pressure Test Outlet Praperly „i <br /> MIN. SEC. PSI PSI PSI MIN. SEC. YES NO .; <br /> -"� TEST yyithout <br /> Q.O.D. +.� <br /> , <br /> >U <br /> With <br /> a . — _. Q.O.D. <br /> r <br /> r <br /> 4 <br /> 14. Date deluge or preaction valve tested � (See Trip Test Table which follows) '"-� � <br /> TRIP TEST TABLE ' <br />� ' <br /> : ,,. . ; <br />$ ;.� Operation ❑ PNEUMATIC ❑ ELECTRIC ❑ HYDRAULIC -�� ; '�� s 'TM�'. <br /> � .. � <br /> Piping Supervised ❑ YES ❑ NO Detecting media supervised ❑ YES ❑ NO � <br /> DEWGE& Does valve operate from the manual trip and/or remote control stations ❑ YES ❑ NO � �� <br /> PREACTION Is there an accessible facility in each circuit for testing Method of testing-circuits °��'��� �'� <br /> ` ❑ YES ❑ NO - � � <br /> - VALVES ;f*„�p��, � <br /> - Does each circuit operate Does each circuit Maximum time to ' <br /> MAKE MODEL su ervision loss alarm o erate valve release o erate release �; � >:�j <br /> ,�y,` YES NO YES NO YES NO t ' s � <br /> � '� ��� `�i� �s <br /> S ' � � <br /> � 'fy` Sd;� "�4�"*� <br />� 15. See Control Valve Maintenance Table. �� '" � � .'��� <br />; Control Valve Maintenance Table �'��.�- �,,�,�,.t� <br />� z Explain �" ���� <br /> Abnormal �*�� <br />��, 7 Control Valves Number Type Open Secured Closed Signs Condition '� � <br /> City Connection Control ' � <br /> � �, Valve � <br /> Tank Control Valves ` ' <br /> - Pump Control Valves � <br />;� - Sectional Control Valves � � <br />� <br /> +� ,. System Control Valves <br /> a +� Other Control Valves ��5 <br /> ,,,,y.' Kitchen Control Valve <br /> � .; <br /> c�; m.* ���`" <br />� 16. Water Flow Test at Sprinkler Riser � °� <br />°�` � °� Water Su ly Source: City Tank Pump `��`�° <br /> ��- Date Test Pipe Size of Static Residual � � <br /> �`' Location Test Pipe Pressure (Flow) <br /> fi Pressure - <br />�, Last Water Flow Test �� <br /> -� This Water Flow Test ! :_- � �'���`�` � <br /> F: . <br /> s� <br /> L �.. - <br /> 17. Explain any "Nd' answers and comments: <br /> :� <br /> z � <br /> ��`�� <br />� s "� � <br /> 18. Adjustments or corrections made during this inspection: s�+, <br /> - `� <br /> 'a� <br /> � z� :� <br />,,<_��� 19. Although these comments are not the result of an engineering review, the following desirable improvements are recommended: <br /> .�; <br /> �; : <br /> Signature: Date: <br />