My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
viking sprinkler info
Orono
>
Property Files
>
Street Address
>
S
>
Shoreline Drive
>
3333 Shoreline Drive- 20-117-23-11-0024
>
Misc
>
viking sprinkler info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:47:47 PM
Creation date
11/30/2018 12:27:30 PM
Metadata
Fields
Template:
x Address Old
House Number
3333
Street Name
Shoreline
Street Type
Drive
Address
3333 Shoreline Drive
Document Type
Misc
PIN
2011723110024
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
., <br /> VIKING AUTOMATIC SPRINKLER COMPANY . <br /> -� 1301 L'ORIENT STREET• ST.PAUL,MINNESOTA 55117 • (651)558-3300 • 1-800-229-6263 •FAX: (651) 558-3310 <br /> r'; <br /> � � SHEET 1 OF 2-Use separate sheet for each building inspection <br /> '�,�`` REPORT OF INSPECTION <br /> _ ,�, <br /> .�- MINNESOTA LICENSE NO. CO0005 WISCONSIN LICENSE NO. SC0000115 <br /> _ ;� <br /> REPORT TO BUILDING OR LOCATION <br /> STREET INSPECTOR <br /> CITY & STATE DATE <br /> �;', <br /> Owner's Section(To be answered by Owner or Occupant) �' <br /> :� A. Explain any occupancy hazard changes since the previous inspection: ;�: <br /> . -3' <br /> •>, s>,; B. Describe fire protection modifications made since last inspection. �- <br /> C. Describe any fires since last inspection. -- <br /> D. When was the system piping last checked for stoppage, corrosion or foreign material? <br /> E. When was the dry-piping system last checked for proper pitch? <br /> F. Are dry valves adequately protected from freezing? <br />- Signature � Title � � Date �� _ <br />;. Inspector's Section (All responses reference current inspection) NA =NOT APPLICABLE <br /> - 1. General ' <br /> a. Is the building occupied?�Yes � No �� � �� ;� <br /> b. Are all systems in service?p Yes ❑No ��'"' � <br /> c. Is there a minimum of 18 in. (457 mm)cleazance between the top of the storage and the sprinkler deflectors?6�--Yes ❑No '- ' <br /> d. Does all electrical heat tape appear to be satisfactory?�Yes ❑No !�-�VA �y +� <br /> e. Does the hand hose on the sprinkler system(s) appear to be satisfactory? - Yes �Na �NA �� <br /> 2. Control Valves(See Item I5.) <br /> a. Are all sprinkler system control valves and all other valves in the appropriate open or closed position?�-Yes ❑No + ��- <br /> b. Are all control valves in the open position locked, sealed or equipped with a tamper switch?�Yes ❑No <br /> 3. Water Supplies (See Item 16.) <br /> a. Was a water flow test of main drain made at the sprinkler riser(s)?�Yes u No � �% <br /> 4. Tanks, Pumps, Fire Department Connections <br /> a. Are fire pumps, gravity tanks,reservoirs and pressure tanks in good condition and properly maintained?❑Yes ❑No C�AfA � � <br /> b. Are fire department connections in satisfactory condition, couplings free, caps in place, and check valves tight?�r3Yes ❑No ❑NA '" <br /> Are they accessible and visible?{�J_Yes ❑No ❑NA � <br /> 5. Wet Systems ti� <br /> a. Are cold weather valves (O.S. & Y.) in the appropriate open or closed position?��'es ❑No ❑NA "��x" <br /> b. Have antifreeze system solutions been tested?❑Yes '�No �--AIA � <br />��� c. Were the antifreeze test results satisfactory?- Yes ` No �-NA �� <br /> } a, d. In areas protected by wet system(s), does the building appear to be properly heated in all areas, including blind attics and perimeter areas � �� <br /> " °" where accessible?t_.�Yes ❑No ❑NA Do all exterior openings appear to be protected against freezing?G�..yes ❑No ❑NA <br /> 6. Dry System(See Items 11 to 13.) <br /> a. Are dry valve(s) in service?❑Yes ❑No �NA - <br /> b. Are the air pressures and priming water levels in accordance with the manufacturer's instructions?❑Yes ❑No @-NA , x �:°, <br /> c. Has the operation of the air or nitrogen supplies been tested?❑Yes ❑No 'r�NA Are they in service?❑Yes ❑No �-�TA •_� <br /> d. Were low points drained during this inspection?❑Yes - No ;NA ' <br /> - e. Did quick-opening devices operate satisfactorily?'` Yes �No �-NA <br /> f. Did the dry valve(s) trip properly during the trip pressure test?❑ Yes �No �-NA <br /> g. Did the heating equipment in the dry-pipe value room(s) operate at time of inspection ?❑Yes ❑No 0 NA '� <br /> f <br /> 7. Special Systems (See Item 14.) �." <br /> a. Did the deluge or pre-action valves operate properly during testing?� Yes �'No C�'�AIt� ' <br /> b. Did the heat-responsive devices operate properly during testing?U Yes �No �NA �•�, <br /> c. Did supervisory devices operate during testing? J Yes ❑No C3-Ia1A <br /> _ 8. Alarms � <br /> a. Did water motor(s) and gong(s)test satisfactorily?CI Yes �J No �1-�IA <br /> b. Did electric alarm(s) test satisfactory?C✓1_Yes r No ❑NA � - <br /> c. Did supervisory alarm service test satisfactory?�Yes `No �J NA <br /> , :. <br /> ; ; 9. Sprinklers <br /> Y � a. Are all sprinklers free from corrosion, loading or obstruction to spray discharge ?�Yes ❑No <br /> - b. Are sprinklers less than 50 years old? (Older sprinklers require sample testing) �'Yes ❑No <br /> T" c. Are quick response and residential sprinklers less than 20 years old?(Older sprinklers require sample testing)[�Yes ❑No <br /> d. Is stock of spare sprinklers available?�Yes -No <br /> ` ' ' e. Does the exterior condition of sprinkler system appear to be satisfactory ?�Yes C No <br /> f. Are sprinklers of proper temperature rating for their locations?�Yes -No <br /> ,; ' 10.Explain any "No" answer and comments: <br /> Signature: � Date: <br />
The URL can be used to link to this page
Your browser does not support the video tag.