., <br /> VIKING AUTOMATIC SPRINKLER COMPANY . <br /> -� 1301 L'ORIENT STREET• ST.PAUL,MINNESOTA 55117 • (651)558-3300 • 1-800-229-6263 •FAX: (651) 558-3310 <br /> r'; <br /> � � SHEET 1 OF 2-Use separate sheet for each building inspection <br /> '�,�`` REPORT OF INSPECTION <br /> _ ,�, <br /> .�- MINNESOTA LICENSE NO. CO0005 WISCONSIN LICENSE NO. SC0000115 <br /> _ ;� <br /> REPORT TO BUILDING OR LOCATION <br /> STREET INSPECTOR <br /> CITY & STATE DATE <br /> �;', <br /> Owner's Section(To be answered by Owner or Occupant) �' <br /> :� A. Explain any occupancy hazard changes since the previous inspection: ;�: <br /> . -3' <br /> •>, s>,; B. Describe fire protection modifications made since last inspection. �- <br /> C. Describe any fires since last inspection. -- <br /> D. When was the system piping last checked for stoppage, corrosion or foreign material? <br /> E. When was the dry-piping system last checked for proper pitch? <br /> F. Are dry valves adequately protected from freezing? <br />- Signature � Title � � Date �� _ <br />;. Inspector's Section (All responses reference current inspection) NA =NOT APPLICABLE <br /> - 1. General ' <br /> a. Is the building occupied?�Yes � No �� � �� ;� <br /> b. Are all systems in service?p Yes ❑No ��'"' � <br /> c. Is there a minimum of 18 in. (457 mm)cleazance between the top of the storage and the sprinkler deflectors?6�--Yes ❑No '- ' <br /> d. Does all electrical heat tape appear to be satisfactory?�Yes ❑No !�-�VA �y +� <br /> e. Does the hand hose on the sprinkler system(s) appear to be satisfactory? - Yes �Na �NA �� <br /> 2. Control Valves(See Item I5.) <br /> a. Are all sprinkler system control valves and all other valves in the appropriate open or closed position?�-Yes ❑No + ��- <br /> b. Are all control valves in the open position locked, sealed or equipped with a tamper switch?�Yes ❑No <br /> 3. Water Supplies (See Item 16.) <br /> a. Was a water flow test of main drain made at the sprinkler riser(s)?�Yes u No � �% <br /> 4. Tanks, Pumps, Fire Department Connections <br /> a. Are fire pumps, gravity tanks,reservoirs and pressure tanks in good condition and properly maintained?❑Yes ❑No C�AfA � � <br /> b. Are fire department connections in satisfactory condition, couplings free, caps in place, and check valves tight?�r3Yes ❑No ❑NA '" <br /> Are they accessible and visible?{�J_Yes ❑No ❑NA � <br /> 5. Wet Systems ti� <br /> a. Are cold weather valves (O.S. & Y.) in the appropriate open or closed position?��'es ❑No ❑NA "��x" <br /> b. Have antifreeze system solutions been tested?❑Yes '�No �--AIA � <br />��� c. Were the antifreeze test results satisfactory?- Yes ` No �-NA �� <br /> } a, d. In areas protected by wet system(s), does the building appear to be properly heated in all areas, including blind attics and perimeter areas � �� <br /> " °" where accessible?t_.�Yes ❑No ❑NA Do all exterior openings appear to be protected against freezing?G�..yes ❑No ❑NA <br /> 6. Dry System(See Items 11 to 13.) <br /> a. Are dry valve(s) in service?❑Yes ❑No �NA - <br /> b. Are the air pressures and priming water levels in accordance with the manufacturer's instructions?❑Yes ❑No @-NA , x �:°, <br /> c. Has the operation of the air or nitrogen supplies been tested?❑Yes ❑No 'r�NA Are they in service?❑Yes ❑No �-�TA •_� <br /> d. Were low points drained during this inspection?❑Yes - No ;NA ' <br /> - e. Did quick-opening devices operate satisfactorily?'` Yes �No �-NA <br /> f. Did the dry valve(s) trip properly during the trip pressure test?❑ Yes �No �-NA <br /> g. Did the heating equipment in the dry-pipe value room(s) operate at time of inspection ?❑Yes ❑No 0 NA '� <br /> f <br /> 7. Special Systems (See Item 14.) �." <br /> a. Did the deluge or pre-action valves operate properly during testing?� Yes �'No C�'�AIt� ' <br /> b. Did the heat-responsive devices operate properly during testing?U Yes �No �NA �•�, <br /> c. Did supervisory devices operate during testing? J Yes ❑No C3-Ia1A <br /> _ 8. Alarms � <br /> a. Did water motor(s) and gong(s)test satisfactorily?CI Yes �J No �1-�IA <br /> b. Did electric alarm(s) test satisfactory?C✓1_Yes r No ❑NA � - <br /> c. Did supervisory alarm service test satisfactory?�Yes `No �J NA <br /> , :. <br /> ; ; 9. Sprinklers <br /> Y � a. Are all sprinklers free from corrosion, loading or obstruction to spray discharge ?�Yes ❑No <br /> - b. Are sprinklers less than 50 years old? (Older sprinklers require sample testing) �'Yes ❑No <br /> T" c. Are quick response and residential sprinklers less than 20 years old?(Older sprinklers require sample testing)[�Yes ❑No <br /> d. Is stock of spare sprinklers available?�Yes -No <br /> ` ' ' e. Does the exterior condition of sprinkler system appear to be satisfactory ?�Yes C No <br /> f. Are sprinklers of proper temperature rating for their locations?�Yes -No <br /> ,; ' 10.Explain any "No" answer and comments: <br /> Signature: � Date: <br />