Laserfiche WebLink
� � I � ��• .� • • •- • • • �- • .• <br /> ���� BOSCH <br /> � <br /> Invented for life <br /> D7050 Series Addressable Photoelectric <br /> Smoke and Smoke Heat Detector Heads <br /> —T�''1 ► Connects to the multiplex bus of the D7024 <br /> ».�^.::,�:: <br /> Addressable FACP <br /> '� r\ ► Superior dust immunity <br /> � ' '/ ► Exclusive Chamber Check self-diagnostics <br /> r <br /> � ' � r� ► Automatic sensitivity test features <br /> �� � '� : 1� ► Easy disassembly for cleaning <br /> � ���� <br /> � <br /> � <br /> The D7050 Photoelectric Smoke and Smoke Heat Detector Functions <br /> Heads are UL Listed, open-area photoelectric smoke Detector Head and Base System <br /> detectors designed for use with commercial fire protective <br /> signaling systems and household fire warning systems (see The D7050 Photoelectric Smoke and Smoke Heat Detector <br /> NFPA 72, the National Fire Alarm Code).They are Heads are part of a compound system of detector head and <br /> compatible with the D7024 Addressable Fire Alarm Control base.The detector base instalis over a back box and <br /> Panels (FACPs). contains all the wiring.The detector head attaches to the <br /> base by aligning the head with the base and turning it <br /> They detect large smoke particles by scattering light from a clockwise. No tools are required for installation other than <br /> pulsed infrared source operating with a gated, high-speed, the hex key used to tighten the tamper screw.Each detector <br /> photodiode infrared sensor.The symmetry of the optical head requires a D7050-B6 detector base. <br /> chamber allows 360° uniform smoke entry, but minimizes Chamber Check Self-diagnostics <br /> external light entry. <br /> The detector meets NFPA guidelines for sensitivity testing, <br /> Use both of these smoke detectors for detection circuits because you can visually inspect the detector and check the <br /> installed in areas where personnel are present.The flash rate of the LED.If the calibration is out of factory-listed <br /> D7050TH has an added fixed-temperature sensor.This range,the LED on the detector double flashes once every 3 <br /> expands the detector application to confined areas where sec to 8 sec. Follow the instructions provided with the <br /> a fire increases air temperature slowly and where there is a detector to clean it.The detector also sends a dirty chamber <br /> substantial increase in air temperature before the fire report to the control panel. <br /> breaks confinement, such as furnace rooms, closets, and <br /> other confined areas. LED Operation <br /> When the detector is operating normally, the LED flashes <br /> once every 3 sec to 8 sec. In alarm, the detector flashes at <br /> least once per second. <br /> Magnetic Test Feature <br /> Test the detector's operation by placing the SMK-TM Test <br /> Magnet next to the detector's LED for three consecutive <br /> flashes.This causes the detector to send an alarm. <br /> www.boschsecurity.com <br />