My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Re: MN Dept of Labor-Industry/report on plans-2005/2009
Orono
>
Property Files
>
Street Address
>
S
>
Shadywood Road
>
2377 Shadywood Road - 17-117-23-44-0009
>
Correspondence
>
Re: MN Dept of Labor-Industry/report on plans-2005/2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:44:11 PM
Creation date
10/9/2018 11:08:04 AM
Metadata
Fields
Template:
x Address Old
House Number
2377
Street Name
Shadywood
Street Type
Road
Address
2377 Shadywood Road
Document Type
Correspondence
PIN
1711723440009
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Eclectic Spalon <br /> Plumbing <br /> Plan No. PLB 1102-00114 <br /> Page 3 <br /> February 25,2011 <br /> 12. Equipment used for heating water or storing hot water shall be protected by approved safety devices in <br /> accordance with Minnesota Rules, part 4715.2210 and-part 4715.2230. Verify that a temperature and <br /> pressure relief valve is provided for the water heater. � <br /> 13. The installation of cross-link polyethylene(PEX)tubing was specified for the water distribution system. If <br /> all of the following requirements cannot be met, a different material that complies with Minnesota Rules,part <br /> 4715.0520 must be used: <br /> a. The tubing system must comply with ASTM Standard F877 and F876. <br /> b. When installed as a system in accordance with ASTM Standazd F877,the system tubing and fittings <br /> must be of the same manufacturer. <br /> c. When other fittings are used with ASTM Standard F877 and F876 tubing,the fittings must comply and <br /> be marked with ASTM Standard F1807,F1960,F2080,F2098-01, or F2159. In addition,the tubing <br /> must be mazked to indicate the fitting standard and the corresponding tubing standard(e.g.ASTM <br /> F877/F876/F1960,F877/F876/F1807;etc.). <br /> d. The system must be insta.11ed by a factory trained installer of the particular PEX system to be installed. <br /> Certain manufacturers require installation by licensed plumbers who have been trained to install their <br /> material. <br /> e. All persons installing PEX materials shall have a card on their possession documenting completion of <br /> h�aining by the manufacturer or his agent for the material to be installed. <br /> f. The tubing and fittings must be marked as required by the applicable standard spec�cation and with the <br /> appropriate ASTM designations by the manufacturer. <br /> g. The installation must be in accordance with the manufacturer's installation instructions. <br /> 14. If PVC pipe is used for the drain,waste and vent system: <br /> a. It must comply with ASTM Standard D2665,D2949, or F891. L <br /> b. It must be installed in accordance with Minnesota Rules,part 4715.0580(F)and part 4715.0600. <br /> Above-grade horizontal runs of pla.stic waste and vent pipe cannot exceed 35 feet in total length. <br /> Above-grade vertical stacks constructed of plastic pipe may exceed 35 feet in total height only if an <br /> approved expansion joint is used. <br /> c. Solvent weld joints must include use of a primer which is of contrasting color to the pipe and cement <br /> (see Minnesota Rules,part 4715.0810, subpart 2). <br /> 15. The water distribution system shall be disinfected in accordance with Minnesota Rules,part 4715.2250. <br /> 16. The plumbing system sha11 be tested in accordance with Minnesota Rules,part 4715.2820. <br /> NOTES: <br /> 1. The scope of this project consists of the remodel at a salon. The plumbing includes the following: <br /> a. Addition of two shampoo sinks. <br /> b. Plumbing for two pedicure spas. <br /> The fixtures connect to the existing sanitary sewer and to the e�usting water distribution system. <br /> 2. This facility is served by e�sting municipal sewer and e�sting municipal water services. <br />
The URL can be used to link to this page
Your browser does not support the video tag.