My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Re: plan review notes/2004
Orono
>
Property Files
>
Street Address
>
S
>
Shadywood Road
>
2377 Shadywood Road - 17-117-23-44-0009
>
Correspondence
>
Re: plan review notes/2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:44:11 PM
Creation date
10/9/2018 11:06:14 AM
Metadata
Fields
Template:
x Address Old
House Number
2377
Street Name
Shadywood
Street Type
Road
Address
2377 Shadywood Road
Document Type
Correspondence
PIN
1711723440009
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� . a. <br /> . <br /> , <br /> Date; 10-18-2004 <br /> Plan Review Notes <br /> Address; 2377 Shadywood <br /> Project; Addition-Remodel, Coffee Shop <br /> Architect; Martin Woody <br /> Contractor; Owner <br /> Owner; Christine Valerius <br /> Inspector; Lyle Oinan <br /> Occupancy Classification; I.B.C. section 303.1 A-2 Occupancy(main Floor) <br /> I.B.C. section 311.1 S-2 Occupancy (Second floor) <br /> Constniction type; VB <br /> Location on property; > 30' to property lines, no requirements <br /> Allowable Height and floor area; <br /> Height, 1 story Max- 2 story allowed with sprinkler -proposed 2 story <br /> Basic allowable floor area 9000 sq. ft. -4256 proposed <br /> Means of egress; Occupant load -Baseinent; 800 square feet divided by 300 = 2 occupants <br /> -15t floor 1440 divided by 15 = 96 occupants <br /> _2°a floor 1376 divided by 300 = 4 occupants <br /> Total 102 occupants <br /> Egress width; table 1003.2.3 <br /> Basement - 2 times .15 = .3 <br /> 1'` floor - 96 times .15 = 14.4 <br /> 2"d floor - 4.5 times .15 = .675 <br /> Total required= 15.375, Proposed 180 inches <br /> Number of exits; table 1004.2.1 Group A>50 occupants req. 2 exits -4 proposed <br /> Requirements; <br /> -I.B.C. 302.1.1, 302.33 and table 302.1.1 requires a one hour separation between group A2 <br /> and S2 <br /> -I.B.C. 1003.2.10.1 Exit signs required when more than 1 exit is required <br /> -I.B.C. 1003.2.10.4 Exit illumination required <br /> -I.B.C. 1003.2.12.1 Guards required to be 42" high when more than 30" of grade <br /> -I.B.C. 1003.3.1.2 Exit doors must swing in the direction of travel <br /> -I.B.C. 1003.2.2.5 Occupant load signs required <br /> -I.B.C. 1003.3.1.4 Floor elevations must be the same on each side of doors <br /> -I.B.C. 1003.3.1.9 Each door in a means of egress from an occupant load of 100 or more <br /> shall be provided with panic hardware <br /> -I.B.C. 1003.3.3.1 Existing stairs must be min. 36' wide <br /> -I. B.C. 1003.3.3.2 Stairways shall have a min. head room of 80" <br /> -I.B.C. 1003.3.3.3 as amended by state code section 1003.3.3.3 exception 5, Requires <br /> stairs to have 8" max rise and 9" min. tread (existing private stairs) <br /> -I.B.C. 2902.1 as amended by state code section 1305.2902 .2 Where plumbing fixtures are <br /> required, separate facilities are required for each sex <br /> j✓(�")G��� Z <br />
The URL can be used to link to this page
Your browser does not support the video tag.