Laserfiche WebLink
, , <br /> REScheck Inspection Checklist <br /> . 2000 Minnesota Energy Code <br /> REScheckSoftware Version 3.5 Release ld <br /> DAT'E: 10/15/03 <br /> PROJECT TITLE: STONEBAY CONDOMINIUMS <br /> PLAN REVIEW AND INSPECTION ISSUES <br /> This list of items may be helpful for Plan Reviewers and Building Inspectors to use as a guide for enforcing the <br /> Minnesota Energy Code. The items apply to Group R, Division 3 Occupancies, one-and two-family residential <br /> dwellings. "The items marked with*apply only to detached one-and two-family <br /> residential dwellings. <br /> PLAN REVIEW ISSUES <br /> FOUNDATION INSPECTION <br /> [ ] foundation wa11 insulation R-5 minimuxn <br /> [ ] foundation insulation extends from top of wall down to top of the footing <br /> [ ] exterior foundation insulation is covered by a protective coating finish <br /> CONCRETE SLAB OR UNDER-SLAB INSPECTION <br /> [ ] slab on grade perimeter insulation R-5 minimum <br /> [ ] slab insulation extends from top of slab to design frost line or top of footing <br /> [ ] floors over unheated space R-30 minimum <br /> WINDOWS/DOORS/SKYLIGHTS <br /> [ � average U-value is 0.37 maximum for windows and glass doors (excludes foundation windows) <br /> [ ] window U-values consistent with building plan and RES check Certificate <br /> [ ] window and door areas consistent with building plan and RES check Certificate <br /> MECHANICAL VENTILATION ISSUES <br /> [ ] residential mechanical ventilation system provides adequate ventilation per code requirements* <br /> [ ] furnace efficiency is consistent with RES check Certificate or building plan <br /> [ ] protection against excessive depressurization is installed per code requirements* <br /> ENVELOPE INSULATION FOR PLAN REVIEW <br /> [ ] interior basement insulation R-5 minimum(if no exterior insulation) <br /> [ ] ceilings with attics R-38 minimum or consistent with building plan and RES check Certificate <br /> [ ] wa11 framing and insulation level is consistent with building design and RES check Certificate <br /> INSPECTION ISSUES <br /> CONCEALED INSULATION <br /> Framing and Sheathing <br /> [ ] wind wash barrier installed at attic edge <br /> [ ] e�terior wall comers framed so that insulation can be installed after exterior sheathing is installed <br /> [ ] intersections of interior partition walls and e�erior walls framed so that insulation can be installed between the <br /> partition and exterior sheathing after e�cterior sheathing is installed <br /> [ ] gaps between framing less than one-half inch are eliminated by securing framing together or are insulated at the <br /> time of assembly* <br />