Laserfiche WebLink
, , <br /> ' Wall height: 9.0' <br /> Depth below grade: 9.0' <br /> . Insulation depth: 9.0' <br /> Basement Wa112: Wood Frame 116 11.6 4.3 5 <br /> Wall height: 9.0' <br /> Depth below grade: 9.0' <br /> Insulation depth: 9.0' <br /> Basement Wa113: Wood Frame 174 11.6 4.3 7 <br /> Wall height: 9.0' <br /> Depth below grade: 9.0' <br /> Insulation depth: 9.0' <br /> Basement Wall 4: Wood Frame 110 11.6 4.3 4 <br /> Wall height: 9.0' <br /> Depth below grade: 9.0' <br /> Insulation depth: 9.0' <br /> Basement Wall 5: Wood Frame 392 11.6 4.3 16 <br /> Wall height: 9.0' <br /> Depth below grade: 9.0' <br /> Insulation depth: 9.0' <br /> Floor 1: Slab-On-Grade:Unheated 280 5.0 209 <br /> Insulation depth: 4.0' <br /> Furnace 1: Forced Hot Air, 92 AFUE <br /> Air Conditioner 1:Electric Central Air, 10 SEER <br /> Proposed and Maximum U-Factor Averages <br /> Proposed Maximum <br /> Average U-Factor Allowed U-Factor <br /> Above-Grade Windows and Glass Doors 0.297 0.370 <br /> Includes Foundation Windows>5.6 ft2 <br /> COMPLIANCE STAT`EMENT: The proposed building design described here is consistent with the building plans, specifications, <br /> and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 Minnesota <br /> Energy Code requirements in REScheckVersion 3.5 Release ld (formerly MECchecl�and to comply with the mandatory <br /> requirements listed in the REScheckIn 'on C ecklist. <br /> �-- <br /> - � <br /> Builder/Designer�'�'� Date �� ��, 3 <br /> r <br />