<br /> RHV/UC-Residential HVAC Load Calculations '
<br /> Elite Software Develo me�age 4 I�)
<br /> Flare Heating&A/C inc.
<br /> Golden Valley,MN 55427-3700 _ ;
<br /> �System 2 Main level Summary Loads �ar s+eR `�rota� I
<br /> _ __ _ Area Sen
<br /> Component
<br /> ; Descriptian 'Quan Loss' Gain G�ih „ ' Cain �
<br /> 4A Window Double Pane &Storm Clear Glass Wood Frame 818 25,664 0 17,476 17,476 '
<br /> 8M Glass Door pouble Clear Glass Wood Frame 103 5,221 0 1,648 1,648
<br /> 11C Door Metal Polystyrene Core 60 2,595 0 585 585 �
<br /> 121 Wall R-19+ 1/2"Asphlt Board(R-1.3) 2415 12,220 0 3,134 3,134
<br /> 131 Part R-19 + 1/2"Asphlt Board(R-1.3) 346 1,751 0 285 285 �
<br /> 161 Ceiling R-44 Insulation 3748 7,931 0 3,793 3,793
<br /> 20J Floor Over Open Crawl Carpet+ R-30 18 58 0 9 9 �
<br /> Subtotals for structure: 55,440 0 26,930 26,930
<br /> People: 4 920 1,200 2,120
<br /> Equipment: 300 1,200 1,500
<br /> Lighting: 0 0 0 !
<br /> Ductwork: 0 0 0 0
<br /> Infiltration: Winter CFM: 225, Summer CFM: 150 22,080 3,560 3,200 6,760
<br /> Ventilation: WinterCFM: 63, SummerCFM: 63 6,186 1,496 1,345 2,841
<br /> Sensible Gain Total: 33,875 '�,
<br /> Temperature Swing Multiplier: X 1.00
<br /> System 2 Main level Load Totals: 83,706 6,276 33,875 40,151
<br /> _ _. ,
<br /> 'Check Figures _ :
<br /> _.
<br /> Supply CFM: 1,524 CFM Per Square ft.: 0.407
<br /> Square ft. of Room Area: 3,748 Square ft. Per Ton: 1,120.179
<br /> _.__ _ - - _ ,
<br /> System Loads _ ':'
<br /> Total Heating Required With Outside Air: 83,706 Btuh 83.706 MBH
<br /> Total Sensible Gain: 33,875 Btuh 84 %
<br /> Total Latent Gain: 6,276 Btuh 16 %
<br /> Total Cooling Required With Outside Air: 40,151 Btuh 3.346 Tons (Based On Sensible + Latent)
<br /> 3.764 Tons(Based On 75% Sensible Capacity)
<br /> i Notes _ ' ' I
<br /> _ _ _ ,
<br /> Calculations are based on 7th edition of ACCA Manual J.
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads. �