Laserfiche WebLink
3. Finish: See details for particular edge conditions. Treat all joints screw heads and other <br /> depressions in accordance with USG recommendations for Perf-A-Tape joint system. All <br /> outside corners to have metal bead,taped in. All inside comers to have reinforcing. Ends <br /> of boazd where board terminates or abuts other materials to have metal edge,taped in. Spot <br /> exposed fastener dimples on face layers with at least tliree coats of joint compound, <br /> feathered and sanded smooth. <br /> C. Workmanship <br /> 1. Conform to best practice and as recommended by the manufacturer to produce highest <br /> quality work. Mechanics to be thoroughly trained and skilled in the installation of this type <br /> of work. Accomplish work when temperature in the building is between 50 to 70 degrees F. <br /> Provide ventilation to eliminate excessive moisture. Provide protection to all surfaces, <br /> which are covered before building is enclosed,from damage and the elements. Guarantee of <br /> work under this section shall warrant against ridging and beading of joints and popping of <br /> wallboard fastenings. <br /> F. Delivery and Cleanup <br /> 1. This subcontractor shall be responsible for bringing into this project all materials required by <br /> him to complete his work. <br /> 2. Upon completion of this subcontractors work,he shall remove materials not installed in this <br /> project. <br /> END OF SECTION 09250 <br /> GYPSUM DRYWALL <br /> Page 3 of 3 <br />