My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Arch/structural specs for addition
Orono
>
Property Files
>
Street Address
>
A
>
Abingdon Way
>
2180 Abingdon Way - 03-117-23-24-0012
>
Misc
>
Arch/structural specs for addition
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:36:04 PM
Creation date
7/26/2018 3:33:21 PM
Metadata
Fields
Template:
x Address Old
House Number
2180
Street Name
Abingdon
Street Type
Way
Address
2180 Abingdon Way
Document Type
Misc
PIN
0311723240012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
179
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WOOD WINDOWS <br /> 08610 WOOD WINDOWS <br /> SECTION 08610 <br /> TffiS SECTION USES THE TERM"ARCHITECT." <br /> PART 1-GENERAL <br /> 1.1 RELATED DOCUMENTS <br /> A. Drawings and general provisions of Contract,including General and Supplementary Conditions and <br /> Division5l Specification Sections,apply to this section. <br /> 1.2 SUMMARY <br /> A. T'his Section includes the following vinyl-clad wood window types including glazing: <br /> 1. Operating windows <br /> 2. Non-operative(Fixed)Window Units. <br /> B. Related Sections: T'he following sections contain requirements that relate to this section: <br /> 1. Joint sealing between wood windows and adjacent materials is specified in Division 7 <br /> • Section"Joint Sealers." <br /> 2. Trim for exterior wood windows,are specified in Division 6"Finish Carpentry" <br /> 3 Owner shall furnish windows and General Contractor will install. <br /> 1.3 SYSTEM PERFORMANCE REQUIREMENTS <br /> A. Standards: Performance requirements for structural performance,air infiltration,and water <br /> penetration for wood windows are those specified in NW WDAaI.S.a2°Industry Standard for Wood Window <br /> Units." <br /> B. Performance Requirements(Grade 40 Windows): Each required window unit shall comply with the <br /> following performance requirements: <br /> 1. Air Infiltra.tion: Not more than 0.25 cfin per sq.ft.of overall frame area at an inward test <br /> pressure of 1.571bf per sq.ft. <br /> 2. Water Penetration: No water penetration as defined in the test method at an inward test <br /> pressure of 4.43 lbf per sq.ft. <br /> 3. Structural Performance: No glass breakage,da.mage to hardwaze,permanent deformation <br /> that would impair operation of the unit,or residual deflection greater than 0.4 percent of the <br /> span at a positive(inward)and negative(outward)test pressure of 40albf per sq.ft. <br /> 4. Forced Entry Resistance: Provide window units that comply with rec�uirements for <br /> Performance Level 10 when tested in accordance with ASTMaFa588. <br /> 1.4 SUBMI'T'TALS <br /> A. General: Submit the following in accordance with Conditions of the Contract and Divisional <br /> Specification Sections: <br /> 1. Product data for each type of wood window required,including: <br /> a. Standard construction details and fabrication methods. <br /> b. Pmfiles and dimensions of individual components. <br /> c. Data on finishes. <br /> d. Recommendations for maintenance and cleaning exterior surfaces. <br /> e. Layout and installation details, including anchors. <br /> f. Giazing details. <br /> Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.