My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Arch/Structural specs for cabana,pool,hot tub areas
Orono
>
Property Files
>
Street Address
>
A
>
Abingdon Way
>
2180 Abingdon Way - 03-117-23-24-0012
>
Misc
>
Arch/Structural specs for cabana,pool,hot tub areas
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:36:04 PM
Creation date
7/26/2018 3:15:05 PM
Metadata
Fields
Template:
x Address Old
House Number
2180
Street Name
Abingdon
Street Type
Way
Address
2180 Abingdon Way
Document Type
Misc
PIN
0311723240012
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
278
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br /> Design Live Loads ' <br /> � Roof Live Load-40 psf. <br /> � Floor Live Load-40 psf. , <br /> • Balconies and Decks-6Q psf. <br /> • Wind Load- 15 psf. <br /> Foundations � <br /> • Footings are designed for an assumed maximum soii bearing pressure of 2QOOPSP. It shall be the <br /> responsibility of the contractor to verify that this value is achieved at the footing elevations <br /> indicated and without long terxn damaging differential settlemen#to the structure. ' <br /> • Bac�ill material aga.inst the foundation walls shall be granular,free draining and conf.ain not more <br /> than 10%passing#200 sieve <br /> • Minimum soil cover for new exterior footings at bUiIiiing perimeter sha.11 be not less than 3'-6" , <br /> unless required by local building code to be deeper or where reqnired to match existing footing <br /> cover. Soil cover far footings supporting attacheti exterior decks shall he 5-0". <br /> • Unless otherwise noted,footings under exterior and interior bearing walls shall be 12"wider than ' <br /> the wall thicknass x 12"deep and reinforced with 2#4 continuous. <br /> Structural Steel ' <br /> • Codes for Structural Steel design,fabrication and erection. <br /> • AISC Manuel of Steel Construction,ASD,current addition. <br /> • A11 bolts to be 3/4"diameter,ASTM A325,unless otherwise noted.Shop connections may be <br /> welded. ' <br /> • All bearn web copes shall be mada to a 1"minimum radius. <br /> • Provide shop drawings for all structural steel items. <br /> Wood Framing � <br /> • Code:NFPA National Design Specification for Wood Construction,latest edifion. <br /> • Shop drawings are required for all Microiam and Glulam members. ' <br /> • Wood posts made up of 2 x members shali be nailed togetfier @ 18"o.c., each side,staggered <br /> spacin�,nsing IOd nails unlcss otherwise noted. <br /> • Double a!1 floor joists under parallel to span partitions. ' <br /> • Where indicated,joist hangers shall be 18 ga.,face mounted unless noted otherwise. <br /> Genera! ' <br /> • Provide temporary bracing,shoring,etc,to ali structural elemenCs,as required at any stage of <br /> construction,to withstand construction loads or any other usual load during the construction <br /> period. Such hracing shall remain in place as long as rec}uired for safaty until completion of the � <br /> project. <br /> 01030 AL'�ERNATES ' <br /> General <br /> This section includes administrative and procedural requirements governing Altcrnates. , <br /> Procedures <br /> Coordination:Modify or adjust affected adjacent Work as necessary to completely and fully integrate � <br /> that Work into the Project. include as part of each alternate,misceilaneous devices,accessory objects, <br /> and similar items incidental to or required for a complete installation whether or not mentioned as part af <br /> the Alternate. , <br /> SUMMARY 4F WORK Page 2 of 5 <br /> GENERAL REQUIREMENTS , <br />