septic info-including design for general purposes only
Orono
>
Property Files
>
Street Address
>
P
>
Pine View Drive
>
1150 Pine View Drive - 28-118-23-42-0009
>
Septic
>
septic info-including design for general purposes only
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:25:42 PM
Creation date
7/9/2018 11:05:54 AM
Metadata
Fields
Template:
x Address Old
House Number
1150
Street Name
Pine View
Street Type
Drive
Address
1150 Pine View Dr
Document Type
Septic
PIN
2811823420012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSPECTOR CHECKLIST - mound <br /> 11 SU Ninve View Unve <br /> � WEI.L secbacks: 20'to pressure tested sewer line (5 psi for 15 min) <br /> 50'to everything 100'to dispersal area with shallow well <br /> PROPER'TY Li'.�TES setback: 10'to everything <br /> Road setback: platted: 10'prop li�e. Metes ft bounds:out of road easement, or outer ditch. <br /> LAK�:!BLLFI' setback: 20'for bluff. Lakes:GD,_, RD_, NE Protected wettand_. <br /> Building setbacks: 10'for everything, 20'for dispersal area. <br /> WATF.R LI1VE under pressure se 10'to bed,tank Ft sewer line. (else sewer line> 12"below) <br /> � Sewer line 8 bafflie connection (no 90's, 3'between 45's, stope min 1"in 8', max 2"in 8') <br /> (no depth req's, clean out every 100', Sch 40 pipe) <br /> � Septic tank and risers (water tiqht, insutafied� proper depth, existing verified by pumping) <br /> mfg 2250 gallons none <br /> Riser over outtet, riser over intet or center, and 6'+inspection pipe over any remaining baffles. <br /> No effluent filter tt alarm <br /> Dose tank risers and piping �water tight, insulated, proper depth, drainback) <br /> mfQ 7 300 gattons <br /> � dose pump 38 gpm 19 head VERIFY PUMP CURVE 5.3 min ON 9 hr OFF <br /> � float setting drop 7.8 inches at 25.5 gpi `DESIGNED" 4.9 inches approx float tether length <br /> 200.0 gal dose divided by gpi "INSTALLED"= inches float drop(field corrected <br /> LABEL pump requirements and drawdown on rtser or panel <br /> Cam lock reachabte from grade• 30"max. J-hook weep hole. Supply tine access (no hard 90's) <br /> 2.0 inch supply pipe: Sch40, stoped 1/8`+, supported by 4"sch40 sleeve or compacted, and buried 6"+. <br /> splice box/ control panel /electrical connections <br /> flow measurement� CT, ETM, time dosed, home water meter <br /> mound absorption area rough up <br /> mound rock dimensions 10.0 X 31.3 <br /> Sand tift depth 14 inches. (Jar test: 2"sand leaves< 1/8"silt after 30 min) <br /> � Absorption Sand beyond rock 0.0 upslope 10.0 downslope <br /> � Bermed topsoil beyond rockbed 11 upslope 12 s9deslope 12 downslope <br /> cover depth of 12-18"+ VERIFY <br /> 3 taterais {f-2'from edge of rock) <br /> 2.00 inch pfpe size (Sch40 pipe&fittings) <br /> 3.0 ft taterat spacing <br /> 8 7/32 inch perforations <br /> 3.0 ft perfarat�on spacing <br /> Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br /> clean outs (no har'�90's) <br /> 4"inspection pipe tn bottom of rock, anchored VERIFY <br /> Abandon existing system- if necessary �Re-use existing tank certification <br /> monitoring plan and type <br /> well abandonment fortn - if necessary <br />