septic design-general approval only
Orono
>
Property Files
>
Street Address
>
P
>
Pinehurst Court
>
650 Pinehurst Court - 06-117-23-34-0006
>
Septic
>
septic design-general approval only
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:23 PM
Creation date
7/9/2018 9:13:07 AM
Metadata
Fields
Template:
x Address Old
House Number
650
Street Name
Pinehurst
Street Type
Court
Address
650 Pinehurst Ct
Document Type
Septic
PIN
0611723340006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSPECTOR CHECKLIST - mound <br /> 65U Ninehurst(.ourt <br /> � WELL setbacks: 20'to pressure tested sewer line (5 psi for 15 min) <br /> 50'to everything 100'to dispersal area with shatlow well <br /> AROPERTY LtNES secback: 10'to everything <br /> Road setback: ptatted: 10'prop line. Metes£c bounds: out of road easement, or outer ditch. <br /> I.AKE/BLUFF setback: 20'for btuff. Lakes: GD_, RD_, NE_. Protected wetland_. <br /> Building setbacks: 10'for everything, 20'for dispersal area. <br /> WATER LINE under pressure se 10'to bed,tank 8 sewer tine. (else sewer line> 12"below) <br /> � Sewer line&baffle connection (no 90's, 3'between 45's, slope min 1"in 8', max 2"in 8') <br /> (no depth req's, clean out every 100', Sch 40 pipe) <br /> � Septic tank and risers (waqer tight, insulated, proper depth,existing verified by pumping) <br /> mfg 2250 gatlons none <br /> Riser over outlet, riser over inlet or center, and 6"+inspection pipe over any remaining bafftes. <br /> No effWent filter 8 atdrm <br /> Dose tank risers and plping (water tight, insulated, proper depth, drainback) <br /> mfg 1300 gallons <br /> � dose pump 29 gpm 25 head VERIFY PUMP CURVE 5.8 min ON 9 hr OFF <br /> � float setting drop 6.4 inches at 25.5 gpi "DESiGNED" 4.3 inches approx float tether tength <br /> 169}0 gat dose divided by gpi "INSTALLED"� inches float drop(field corrected <br /> LABEI pump requir{ements and drawdown on riser or panel <br /> Cam lock reachable from grade-30"max. J-hook weep hole. Supply line access (no hard 90'sj <br /> 2.0 inch supply pipe:Sch40, stoped 1/8"+, supported by 4"sch40 steeve or compacted, and buried 6"+. <br /> sptice box /control panel/electrical connections <br /> flow measurement: CT, ETM, time dosed, home water meter <br /> mound absorption area rough up <br /> mound rock dimensions 10.0 X 50.0 <br /> Sand lift depth 2�_inches. (Jar test: 2"sand teaves< 1/8"silt after 30 min) <br /> � Absorption Sand beyond roKk 0.0 upstope 17.0 downslope <br /> � Bermed topsoil beyond rockbed 13 upslope 14 sideslope 23 downslope <br /> cover depth of 12-18"+ VERIFY <br /> 3 laterats (1-2'from edge of rock) <br /> 2.00 inch pipe size (Sch40 pipe f�fittings) <br /> 3.0 ft tateral spacing <br /> 8 7/32 inch pertorations <br /> 3.0 ft perforation spaqing <br /> Air inlet at end of lateratsr and at top feed manifold if necessary. VERIFY <br /> clean outs (no hard 90's) <br /> 4"inspection pipe to bottom of rock, anchored VERIFY <br /> Abandon existing system-af necessary �Re-use existing tank certification <br /> monitoring plan and type <br /> well abandonment form -lif necessary <br />