My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic design-general approval only
Orono
>
Property Files
>
Street Address
>
P
>
Pinehurst Court
>
650 Pinehurst Court - 06-117-23-34-0006
>
Septic
>
septic design-general approval only
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:23 PM
Creation date
7/9/2018 9:13:07 AM
Metadata
Fields
Template:
x Address Old
House Number
650
Street Name
Pinehurst
Street Type
Court
Address
650 Pinehurst Ct
Document Type
Septic
PIN
0611723340006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br /> 2250 �alton Septic tank (minimum) Tank options: none <br /> �uro iaiger �ann wi�n tnuiup�e c�rn�r�ann5 <br /> 1300 gatlon dose tank (minimum) at 25.49 gpi <br /> 29 GPM C� 25 ft. of head, Pump required <br /> 6.6 inch swing on Demand float which translates to roughty 4.3 inches of ftoat tether length <br /> if time dosing is required --> 5.8 minutes ON time& �hours OFF time <br /> 19 inches from bottom of tank to"pump ON"float, or 12 inches to"timer ON"float <br /> 22 inches from bottom of tank to"Hi Levet Alarm"or 32 inches to"Hi level alarm"if time dosed <br /> 110 ft. of 2.0 inch supply line with end feed manifold connection <br /> (Tip: "top feed" manifotd to control drainback} <br /> 24 inch, or 2.0 ft. Sand Lift Mound <br /> 10.0 ft. wide by 50.0 ft. tong Rock bed <br /> 3 laterals 2.00 inch diameter 48.0 ft. long 3.0 ft. laterat spacing <br /> 7/32 inch perfs 3.0 ft. perforation spacing <br /> No Effluent filter Et alarm <br /> 3 clean out 8 valve box assemblies <br /> 27.0 ft.Total sand ABSORPTION width (minimum) <br /> 0.0 ft. upslope and sideslope (sand beyond rockbed, minimum} <br /> 17.0 ft. Downslope (sand beyond rockbed, minimum} <br /> Specific slope ratios give BERM widths (topsoil beyond rockbed)of: <br /> 4:1 upslope ratio 13 ft. upstope berm <br /> 3:1 sideslope 14 ft. sideslope berms <br /> 4:1 downslope 23 ft. downslope berm <br /> 4" inspectian pipe <br /> 18" ca�er on top <br /> U slo e berm �3 Downslo e berm 23 <br /> �—.,�,_ -12" cover on sides <br /> (6"loamy cap&r5"topsoil) <br /> 2.0 Ctean sand tift <br /> � 1.0 Depth to Limitin� <br /> L9'mitingCdn'dition � _`___-----____ <br /> Absor tion Width 27•� ��^��—` ----------- <br /> Note: <br /> For 4 to 1�slopes, Absorption Width is measured from the Bedequally in both directions. <br /> FQr slo�es >1%, Absorption Width is measured downhilt from Che upslope edge of the Bed. <br /> Rock Bed: 17.0 Yd3 or*1.4= 24 ton 6 inches under pipe <br /> Mound Sand: 208 yd3 or"1.4= 292 ton calculation based on 3:1/4:1 slope from top of rockbe� <br /> Loamy Cap: 70 Yd3 or*1.4= 98 ton 6"deep <br /> TopsoiL• 80 yd3 or*1.4= 112 ton 6"deep <br />
The URL can be used to link to this page
Your browser does not support the video tag.