<br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two yeazs.
<br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
<br /> SYST'EM CONFORMITY 1-3 : �
<br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
<br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the cunent Orono
<br /> Municipal Code but does meet the three foot separation requuement or two foot requirement for systems installed 1996 or earlier,and
<br /> which is not failing or an imminent threat to public health or safety.
<br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
<br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any
<br /> reason;and any ISTS with less than three fcet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
<br /> TANK CONDITION(5-7):
<br /> �nk inspection indicates:
<br /> Pumpout not needed at this time. .
<br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. �
<br /> Tank was last pumped )•
<br /> Make sure seutic tanks are aumped throush manhole and not through white inspection oipes. This ailows for the prop_er
<br /> cleanins Keep water softner and iron filter discharee out of seatic svstem to arolon4 life of drainfield.__As_k aumaer to test
<br /> alarm float to verifv alarm is still workine in vour house The alarm warns owner that seotaee is about to backup mto b_a_s_ement.
<br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dra.pipe}must be mstalled�n each tank. If
<br /> tanks have not been pumped out within the last three years,they should be pumped out now.
<br /> D FIELD CONDITION 8-10 : � _
<br /> 8 Drainfield is dry,no surfacing evident. �
<br /> Some evidence of surfacing,not critical yet.
<br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
<br /> immediately.Repairs must be completed within 90 days. �
<br /> � � . � � �'C_._ -�-o�t�' �Qa�
<br /> �
<br /> � COMMENTS: J�'^d, `" � _:
<br /> � .iwa.-N ,Y+ .e..... . �. .,. . ...... . . :.`� .�...,�. � ,
<br /> ,� , ".- ' .1.� � :J�
<br /> _ .,,. f . .... . ...�.i, � �
<br /> u 1.y
<br /> ��
<br /> ��-�� �1 r���:
<br /> I7ate of Inspection Matt�olter�nan- Septic System Inspector
<br /> �t�: s�n the event Cl�at thas inspecti.on report is used'to sakisfy,t�ie cequiPtmenis fiar�n��rt'Egage or�ttier f�ansftlr df property.'be atfvised that this repatt do�s
<br /> � t�st gi�irFuitee oc cercify that an e�iStistg systcm �vitl eGntinut Eo fvnetidn properly but GS rt�ere�y a� rnRinion of the �Itq�r��y o�the 5yst�m ctnder x�rte�t
<br /> � ':;-� �.:�. .��td�S h�e�t£in�&�ifab�e tnteTm�h�4A::.w. � � ,,. .M �.,,.rw " � � . {,� � ,�. '� ��� ;, � r� ' �
<br /> _ ,�.w �.`�i_.r.�.,Y�`e.c .m a'nw.�', s�.,_ .,i��� ^�`�'�'�i .r"5� >� .x.as" _`>». .,z;r ... ,"�r-' �� ,
<br />
|