Laserfiche WebLink
S-P TESTING, INC. <br />951 KATYDID LANE <br />ST. MICHAEL MN 55376 <br />497-3566 <br />Roland Euler <br />Lot 10, Block 1 <br />Stielows Add. <br />Orono, Henn. Co., MH <br />STEVE SHIRMERS <br />December 1, 1987 <br />5' <br />This system is designed~for a Type 1, four bedroom home and in accordance <br />with the Minnesota Pollution Control Agency standards WPC 40 and local <br />ordinances. <br />The soils on this,site are typical of SCS soils mapped - LrB - Lester loam. <br />A seasonally high water table was located at 22", 26", & 34", (mottling). <br />Due to the seasonally high water table, a pressurized mound system will <br />need to be installed. The bottom of the rock bed must be located at <br />least 3' above the seasonally high water table. <br />The soils at a depth of 18" have a percolation rate averaging 37.2 rain/inch <br />and are adequate for treating septic effluent. <br />A pumping chamber will need to be installed to lift the effluent to the <br />treatment area. <br />The manifold and supply line pipe must have back drainage to the pumping <br />chamber. The distribution pipes shall have their ends capped. Be sure <br />the rock and sand fill material are clean. The sod layer below the <br />entire mounded area must .be turned over, just break up the sod, be sure <br />not to over work. <br />The power supply and switches must be located outside the manhole and <br />pumping chamber in-a weather proof enclosure. A warning device must be <br />installed with a light and sound device, this is in case of a pump failure. <br />(Mercury floats are a good method). <br />All neighboring wells-are located more than 75' away from the proposed <br />treatment area. <br />Keep all heavy equipment off of the proposed treatment area before and <br />after construction as much as possible. The treatment area should be <br />marked off before construction. <br />With proper installation and maintenance, this system should have no <br />problenT in treating septic effluent effectively. <br />It is recommended that the septic tanks be pumped every 2 years. <br />Soil mitd FercofaNoR ' —---------- <br />SyieiR <• Steven B. Schirmers <br />SBS/ds