10-23-1985 Septic System Design Memo
Orono
>
Property Files
>
Street Address
>
A
>
Abingdon Way
>
2205 Abingdon Way - 03-117-23-24-0005
>
Septic
>
10-23-1985 Septic System Design Memo
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:35:47 PM
Creation date
1/31/2023 1:21:34 PM
Metadata
Fields
Template:
x Address Old
House Number
2205
Street Name
Abingdon
Street Type
Way
Address
2205 Abingdon Way
Document Type
Septic
PIN
0311723240005
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM DESIGN <br />FOR SHAVER CORPORATION <br />LOT 4, BLOCK I, ABINGDON GLEN <br />ORONO, MINNESOTA <br />10-23-85 <br />1. Percolation Rate, Type of System. <br />16.0 minutes per inch for the primary site(hoIes 1-4). Standard system with <br />trenches no deeper than 2 feet in the natural soil. <br />2. Proposed Flow Rate. <br />600 G.P.D. <br />3. Soil Treatment Area Required. <br />600 G.P.D. X 1.67 percolation rate factor = 1000 Sq. Ft. <br />4. Size and Number of Trenches. <br />3 trenches 3 feet wide and 111 feet long = 1000 Sq. Ft. These trenches would <br />be spaced a minimum of 7.5 feet apart center and be 1-2 feet deep in the na <br />tural soil. <br />5. Drainfield Rack Needed. <br />55.6 cubic yds. of rock is needed to have 12 inches under and 2 inches over <br />a 4 inch distribution pipe. <br />6. Septic Tanks. <br />Two septic tanks each of 1000 gallons are recommended. It appears that grav <br />ity flow can be used to reach the drainfield area if the house is kept high <br />enough. If not, then a third pumping t.vok and pump would be needed. <br />7. Additional Information. <br />Grading should be done to divert runoff water away from the drainfield area. <br />No grading or construction traffic is allowed in either drainfield area and <br />all construction and materials should adhere to the provisions of the City <br />of Orono. <br />If there are any other questions, please contact me. <br />Sincerely, <br />PERCOR, ijc. <br />Mark S. Gronberg, P.E. ^ <br />PCA certified