My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
MN Dept Labor/industry-report on plans
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0795 Old Crystal Bay Road North - 28-118-23-34-0003
>
Correspondence
>
MN Dept Labor/industry-report on plans
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:24:42 PM
Creation date
3/14/2018 11:56:36 AM
Metadata
Fields
Template:
x Address Old
House Number
795
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
795 Old Crystal Bay Road North
Document Type
Correspondence
PIN
2811823340003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
APR-3-2008 02:02P FROM:LONG LAKE PUBLIC WKS 952 4762856 TO:9522494616 P.2 <br /> MINNESOTA DEPARTMENT OF LABOR AND INDUSTRY <br /> Division of Construction Codes and Licensing <br /> REPORT ON PLANS <br /> Plans and specifications on storm sewer and draintile: Orono High School -Track and Field Improvements, 685 <br /> Old Crystal Bay Road,Long Lake,Hennepin County,Minnesota,Plan No. 086925 <br /> OWNERSHIP: Independent School District No.278,c/o Ms.Karen Orcutt,Superintendent,P.O.Box 46, <br /> Long Lake,Minnesota 55356-0046 <br /> SUBMITTER(S): Anderson-Johnson Associates,Inc., 7575 Golden Valley Road, Suite 200,Minneapolis, <br /> Minnesota 55427 <br /> Plans Dated: January 8,2008 <br /> Date Received: March 14,2008 <br /> Date Reviewed: March 31, 2008 <br /> SCOPE: The plans and specifications describe the water service and building sewer connections for the <br /> referenced facility. The review is limited to the design of this particular project only, and does not cover the <br /> plumbing within the building. The review is based upon the supposition that the data on which the design is <br /> based are correct,and that necessary legal authority has been obtained to construct the project. The <br /> responsibility for the design of structural features and the efficiency of equipment must be taken by the project <br /> designer. Approval is contingent upon satisfactory disposition of any requirements included in this report. <br /> Special care should be taken to insure that the material and installation are in accordance with the provisions of <br /> the Minnesota Plumbing Code and applicable licensing requirements. <br /> INSPECTIONS: All plumbing installations,including water service and building sewers,must be tested and <br /> inspected in accordance with the requirements of the Minnesota Plumbing Code. It is the responsibility of the <br /> contractor/installer to notify the Minnesota Department of Labor and Industry when an installation for a state <br /> contract job,licensed facility,or project in an area where there is no local administrative authority is ready for an <br /> inspection and test. To schedule inspections,contact the state plumbing standards representative for your region, <br /> or call Jim Peterson at 651/284-5889. <br /> REQUIREMENT(S): <br /> 1. The discharge of an existing exterior water fountain appears to be shown discharging to the storm sewer <br /> system on the Utility Plan, Sheet No. C7. The Minnesota Pollution Control Agency(MPCA)has <br /> determined that the discharge from a drinking fountain is wastewater and must receive proper treatment. <br /> This means the outdoor drinking fountain must be served by an individual sewage treatment system in <br /> compliance with Minnesota Rules,Chapter 7080 or it must discharge above grade in order to visibly see any <br /> possible contamination. Please verify that a code complying plumbing system will be installed. <br /> 2. The RCP and PVC specified for the storm sewer must comply with Minnesota Rules,part 4715.0540. No <br /> quality standards for these materials are provided on the submitted plans. <br /> 3. Materials used for the subsoil (draintile)drains must comply with Minnesota Rules,part 4715.0620. No <br /> quality standard for this material is provided on the submitted plans. <br /> 4. The storm sewer installation must be tested in accordance with Minnesota Rules,part 4715.2820. <br />