Laserfiche WebLink
+I e <br /> 'O"ITY of ORONO <br /> Municipal Offices <br /> Street Address: c 5%—,A 49-4(*o O Mailing Address: <br /> 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: —7t) <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.. <br /> SYSTEM CONFORMITY (1-3): <br /> 1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated,100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): <br /> Tozk inspection indicates: <br /> 5) Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ) <br /> Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the proper <br /> cleaning Keep water softner and iron filter discharge out of septic system to prolong life of drainfield. Ask pumper to test <br /> alarm float to verify alarm is still working in your house The alarm warns owner that septage is about to backup into basement.. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have"not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION 8-10); <br /> 8 Drainfield is-dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 lir'whfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> U +� <br /> Date of Inspection MattBolterman- Septic System Ipector <br /> w Notr: to the event that this inspection report is used to satisfy the requirements-for a mortgage or other transfer oil ropprty'27e at(vise&that phis report does <br /> tot. uarai�tee or;icerti + (3 at t���sty s s,R nye w1 ,m i n e t4 fdncfsoit properly but cs m ely opnioaa'of qu c the see wader current.:; <br /> s '. .! <br /> �5 Esaidstittnslsascd T311 t114 a1Kalalst ,.Yt��i j}ei ,.,,,a., i..,i,...,•z ,. s',-..as .-- ' ,,1( s ' r <br /> x'+2^1" 'S_ <br />