<br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. � �
<br /> The on-site sewage treatment system at the above address has been inspected and appears to fall intd the categories checked below.
<br /> STEM CONFORMITY 1-3 : �
<br /> "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
<br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and coastruction standards of the curnnt Orono
<br /> Municipal Code but does meet the tttree foat separation roquirement or two foot requirement for systems installed 1996 or earlier,and
<br /> which is not failing or an imminent threat to public health or safety.
<br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an LSTS located within a designated 100-year flood plain,any ISTS which may
<br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any
<br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
<br /> TANK CONDITION f 5-7): .
<br /> Tank inspection indicates: .
<br /> 5 Pumpout not needed at this time. .
<br /> � Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years.
<br /> Tank was last pumped �S"2-7""�— )� .
<br /> Make sure seatic tanks are aumned throueh manhole and not throu�h white insaection aiaes. This allows for the aroaer
<br /> cleanine Keep water softner and iron filter dischar�e out of seatic svstem to arolong life of drainfield. Ask pumper to test
<br /> alarm float to verifv alarm is still workine in vour house The alarm warns owner that seatage is about to backup into ba_s_ement.
<br /> 7 Inspection risers missing-tanks cou(d not be inspected. Inspection risers(4"dia.pipe)must be mstalied in each tank. If
<br /> tanks have not been pumped out within the last three years,they should be pumped out now.
<br /> D INFIELD CONDITION(8-10): �
<br /> 8 Drainfield is dry,no surfacing evident.
<br /> Some evidence of surfacing,not critical yet.
<br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector '
<br /> immediately.Repairs must be completed within 90 days.
<br /> . 1 . '
<br /> .
<br /> r:.p �� �� 1� ���.� , �:.:��... �'� ?� �'�C. �
<br /> ...._ .. coM��r�rs: �- �� �. ��... � S
<br /> �„��5 S v�,c.,.�- 2,u o� - .�
<br /> : ����
<br /> �� . � . .
<br /> Date of Fnspec�ion Matt BQttecrcxan- ;Septic System Inspec�,or
<br /> � ~Note: ln,the event t6at this �nspecti�n report,:is used to��tis�;the requ;tretnents for a�noifgage�rbtl:ter transfer of piroperry."fae ad�ised thaC 3his teporc does
<br /> ws:` d nof,.guacBntee�r cet#ifY�hat ait ea�sting syskem �+��ll c t�nue to�u�et�or�properfy but is marely'an np(nian ot Che adec�uaey af`th�,syste.r�n ctt�tler cttt�renC
<br /> a� ..,:�a'u�'�. .K�w�;I:Q�[��'',E1,85�dtl�C$,�11�,�,�R�''0..7i"a�,n ';n..ts �`�a�'"^�.���.:C�� M,�I; �s .:F .�:s, � � �� y a�� � ,� , .�".�., r:�ml,iu.�� � il �� �. �t , .�.w�:. , .
<br /> .: .. . . _�2^.�u."�r�.";�.��. �'ik as,<u.�S� �S. :� .t du k.i :�`� d...� rar uw � �, . x,me`�
<br />
|