Laserfiche WebLink
� °� <br /> o ; o <br /> ��i��:��:- CITY of ORONO <br /> � ������ - � � <br /> ,� ` � ��p�� titi M�,;��� ot��� <br /> '�' 1 ` .`�.��.° <br /> i�',�, G �15a-a49-'i6o 0 <br /> \ � +,'-�f f.,: ,� Street Address: Mailing Addross: <br /> `��Hp'g' 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> ` �� <br /> To Current Owner: Address: ! � M�f�� �-���/ <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at ihe above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (i-3): � <br /> 1 "CODE SYSTEM"An ISTS which meets all the location,design and conshuction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS wluch dces not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an i�inent threat to public health or safety. <br /> �"NON-COMPLIANT SYSTEM" A protubited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may bot meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any LSTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): t7 <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this yeaz (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ). <br /> Make sure septic tanks are aumued through manhole and not throush white insaection uiaes. This sllows for the aroaer <br /> cleanins Keea water softner and iron filter disc6aree out of seatic svstem to arolon¢life of drainfield. Ask uumaer to test <br /> alarm float to verifv alarm is still workin¢in vour house. The alarm warns owner that septa�e is about to backua into basement <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> D IELD CONDITION 8-10 : ,�, <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield.is saturated and visibly discharging untreated ei�luent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENT�S. �f�y t��F-_.c�(l 1S rUh- C U� 1'[,�j d-- /`'`v�Y �� <br /> _�(�1��c�-t,1 b,�r \�=31-'2,.01 U , ✓•-� 1 t��i L fiFn1l' d v�..*�-r r 2 a c'3- <br /> °��1-0� G� <br /> Date of Inspection Matt Bolterman- Septic System Inspector <br /> Note: In the ev�t that this inspection report is used to satisfy the requ'u�ents for a mortgage or other transfer of property,be advised that this report does <br /> not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> conditions based on the available int'ormation. <br />