Laserfiche WebLink
.. SEPTIC SYSTEM INVENTORY <br /> . r <br /> Address: 1180 Lyman Ave. PID: 35-118-23 43 0023 <br /> Building Type residence BRs Install'd for: 4 In Musa: No <br /> Permit#: 8971 Date of Permit: 4/21/87 Installer: Quickway Exc. <br /> System Type: standard trench Experimental: no Tank Filter: <br /> SYSTEM CONDITION <br /> Conformity: 1 Tank Condition: 6 DF condition: 11 Failure Pot: low <br /> SEPTIC TANKS <br /> Material: precast concrete Capacity: 1000, 1000 <br /> Setback to Bldg: 20 Cesspool: no <br /> DRAINFIELD <br /> Length of Lines: 400 # Lines: 4 Trench Width: 3 <br /> Treatment Area: 1200 Type of Filter: rock Soil Boring: yes <br /> Tile Size: 4 Under Tile: 12 Perc Rate: 40 <br /> Setback DF-Bldg: 50 DF Ht above Wt: 3 <br /> Soil Type: sandy clay loam Limitations: none <br /> WELL DATA <br /> Setbacks - Well-Tanks: 80 Well-DF: 100 Report in File yes <br /> Pump Type: subm. Depth: 310 Diameter: 4 Method: drilled <br /> INSPECTION RECORD PUMPO UT RECORD <br /> DATE DESCRIPTION COMPLIANCE DATE GALLONS <br /> ;� <br /> 4/22/87 installation 1 9/1/90 2000 <br /> 10/1/90 no surfacing 1 7/1/91 2000 <br /> 10/22/92 no surfacing 1 5/1/92 2000 <br /> 4/22/94 no surfacing 1 9/11/96 2000 <br /> 9/12/96 conforming-no surfacing 1 <br /> 12/18/97 no surfacing 1 <br /> 7/16/98 no surfacing 1 <br /> 8/2/00 no surfacing, pump tanks 1 <br /> 8/26/02 no surfacing,pump tanks code system <br /> �"�IV "Q(:) �DuS� ��Or.� <br />