Laserfiche WebLink
� ��' _ <br /> O O <br /> �i CITY of OR4N0 <br /> _��:��., <br /> �a '����'��}- _ � <br /> ��, s�; "''. Munici�l offices <br /> ` � � .�r. ,�, <br /> �,t ' �„'��.FF..,,'�,�G Street Address: °ISa-�49-y6o � Mailing Address: <br /> `�x'�HO'g' 2150 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: v��� �^5 v'e`� C:� L 1� <br /> City Ordinance 199 requires that each e�cisting on-site sewage treatment system in Orono be inspected every two years. <br /> `The on-site sewage treatment system at the above address has been inspected and appeazs to fall into the categories checked below. <br /> SYSTEM CONFORMIT'Y (1-3): � <br /> 1 "CODE SYSTEM";An ISTS which meet4 all the location,design and construction standazds of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which dces not meet all the location,design and consiruction standards of the current Orono <br /> Municipal Code but dces meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an i�inent threat to public health or safety. <br /> � "NON-COMPLIANT SYSTEM" A prohibited ISTS;an LSTS located within a designatsd 100-year flood plain,any ISTS which may <br /> or may riot meet all the location,design,or construction stan�rds of t.�e current Orono Municipal Code and which is failing for any <br /> reason;and any IST'S with less than thrce feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDTTION(5-71: � <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> r6�eptic tanks must be pumped out this yeaz (city code recommends tanks to be pumped out once every 3 yeazs. <br /> �JTank was last pumped �-3^0� ), <br /> Make sure seatic tanks are pumped throu¢h manhole and not throu�h white insaection aices. This allows for the uroaer <br /> cleanin�. Keen water softner and iron filter discharse out of sentic svstem to arolon¢life of drainfield. Ask uumper to test <br /> alarm float to verifv alarm is still workine in vour 6ouse. The alarm warns owner that seata¢e is about to backua into basement <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION 8-10 : � <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: �s"=���c\� iS ror.— C o,.— \:�.,,�y— d-- r1�S-r �� r� 1��t � <br /> b �t=3 �—Zo�v v� S� �-,, L 3-���1 � Sti.�.�r Zoo� , <br /> � �za —Qy Glr—� <br /> Date of Inspection Matt Bolterman- Septic System Inspector <br /> Note: In the event that this iaspection report is used to sa6sfy the requirements for a mortgage or other transfer of property,be advised that this report dces <br /> not guarantee or certify that an existing system will wntinue to function properly, but is merely an opinion of the adequacy of the system under cutrent <br /> conditions based on the available infoimation. <br />