<br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
<br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
<br /> SYSTEM CONFORMITY (1-3): �
<br /> �"CODE-S�'STEM"An ISTS which meets alI the iocation,design and construction standards of the current Orono Municipal Code. - -
<br /> 2 "COMPLIANT SYST'EM" An ISTS which does not meet all the location,design and construction standards of the current Orono
<br /> Municipal Code but does meet the thrce foot separation requirement or two foot requirement for systems installed 1996 or earlier,and
<br /> which is not failing or an�*ro*��nent threat to public heald►or safety.
<br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located wid�in a designated 100-year flood plain,any ISTS which may
<br /> or may not meet all ffie location,design,or wnstruction stan�rds of the ciurent Orono Municipal Code and which is failing for any
<br /> reason;and any LSTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil chazacteristics.
<br /> TANK CONDIT'ION(5-7): �l
<br /> Tank inspection indicates:
<br /> 5 Pumpout not needed at this time.
<br /> 6 Septic tanks must be pumped out this ear (city code recommends tanks to be pumped out once every 3 years.
<br /> Tank was last pumped�0 13^ �� ), �
<br /> Make sure seatic tanks are aumped throu¢h manhole and not throu¢h white insnection aiaes. This sliows for the uroaer
<br /> cleanint. Keeu water softner and iron glter discharee out of seatic svstem to nrolone life of drainfield. Ask uumaer to test
<br /> alarm float to verifv alarm is still working in vour house. The a►arm warns owner that seotase is about to backua into basement.
<br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
<br /> tanks have not been pumped out within the last three years,they should be pumped out now.
<br /> D IELD CONDITION(8-10): �
<br /> �8�i�eld is dry,no surfacing evident.
<br /> 9 Some evidence of surfacing,not critical yet.
<br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
<br /> immediately.Repairs must be completed within 90 days.
<br /> _. _.......
<br /> coM�rrrs: f�•o�� - �, :� �- Sc�-�,�. _ . ��,�n� - _,_ .. _,\.�oic bk-_.. . ...:__
<br /> �S-1�-�y C�^a: ��
<br /> Date of Inspection Matt Bolterman - Septic System Inspector
<br /> Note: In the event that this inspection repon is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report dozs