My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Terrace
>
1802 Lakeview Terrace - 27-118-23-43-0006
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:22:29 PM
Creation date
4/25/2017 11:32:12 AM
Metadata
Fields
Template:
x Address Old
House Number
1802
Street Name
Lakeview
Street Type
Terrace
Address
1802 Lakeview Terrace
Document Type
Septic
PIN
2711823430006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO � O� <br /> Municipal Offices O O <br /> Post Office Box 66 <br /> Crystal eay, MN 55323-0066 � � ON—SITE SEWA(�L TR8AT1�M1' <br /> r�, � INSPECTION REPORT <br /> ti <br /> �� �p <br /> 9k'ESH04 <br /> Owner: l.�[./l�� Qr/L1 �Address: ��Oo� L1J'/G�//�1���� <br /> Permit #'s: Dates: !'�'1Y� Contractors:�'� � <br /> City ordinance nunber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is ,�an existing system [ ] new construction) <br /> SYSTEM CONFORMITT C1-3): <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but aas installed according to the code in effect at the time of installation, and which <br /> is operating satisfectorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface waters. <br /> "NON-CONfORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floo�lain; any <br /> system which mey or mey not meet all the location, design, and construction standards of the current City <br /> Codes and which is faili for any reason; and an system with less t f unsaturated soil or sand <br /> � between the distribution ' ' s, �r I <br /> (The limiting soil charecteristic�as or [ 7 has not been identified a this ti . I the im�t ng soil <br /> characteristic has not been ident ied, this classification may be subject to revision.) <br /> TANK CONDITION C5-10): <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. <br /> 7 Solids accumutation in tanks is at a critical level. Tanks should be puriped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface dischar�e. <br /> 9 Inspection risers missing-tanks could not be inspected. lnspection risers (4" dia. pipe) must be installed in each <br /> tank at next punpout. lf tanks have not been punped out within the last three years, they should be punped <br /> out now. <br /> 10 Inspection pipe is lxated directly over tank baffle (does not give accurate measurement of solids accumulation). <br /> If tanks have not been pun�cd out within the last thre t y shou d be punped out no <br /> DRAINFIELD CONDITION C11-14): <br /> D�fietd inspection indicates: <br /> 1 Drainfietd is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated end visibly discharging �mtreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS (sloae,setbacks.etc.): <br /> POTENTIAL FOR SYSTEM FAILURE tdecends on soils.water table.:etc.): � <br /> O ENTS. � <br /> � H i <br /> ate of Inspection S t' System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that en existing system will continue to function <br /> properly� but is merely an opinion of the adequacy of the system under current conditions besed on the available <br /> informet�on. <br /> This report must be kept on the premises with the system locetion and punping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.