My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic info ( under old address of 2665 Fox St.)
Orono
>
Property Files
>
Street Address
>
G
>
Gander Road
>
730 Gander Road - 04-117-23-43-0021
>
Septic
>
Septic info ( under old address of 2665 Fox St.)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:14:50 PM
Creation date
12/8/2016 1:59:56 PM
Metadata
Fields
Template:
x Address Old
House Number
730
Street Name
Gander
Street Type
Road
Address
730 Gander Rd
Document Type
Septic
PIN
0411723430021
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO � O� <br /> Municipal Offices O � O <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT <br /> „� � INSPECTION REPORT <br /> ti <br /> ���kESH���G <br /> Owner: t, l� � � `, Address: �� �� � �� <br /> Permit �'s• ��� Dates: `:� Contractors: � �t" W- <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is [�an existing system [ ] new construction) <br /> SYSTEM CONFORMITY (1-3): <br /> '� "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and uhich is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface uaters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input uithout discharging <br /> any pollutants into ground or surface waters. <br /> 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the limiting sotl characteristics. <br /> (7he limiting soil characteristic [ ] has or .�h has not been identified at this time. If the limiting soil <br /> characteristic has not been identified, this classification may be subject to revision.) <br /> TANK CONDITION (5-10): L�j <br /> Tpnk inspection indicates: <br /> (� Pumpout not needed at this time. <br /> b Solids accumutation in tanks indicates they should be p�xnped out this year to help prevent future problems. <br /> 7 Solids accumulation in tanks is at a critical level. Tanks should be pu�nped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be pumped out uithin 48 hours to eliminate surface dischar�e. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed tn each <br /> tank at next purtipout. If tanks have not been p�xnped out within the last three years, they should be pu�nped <br /> out now. <br /> 10 ]nspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). <br /> If tanks have not been punped out within the last three years, they should be pumped out now. <br /> DRAINFIELD CONDITION (11-14): <br /> Dr nfield inspection indicates: <br /> � Drainfie[d is dry, no surfacing evident. <br /> TZ Some evidence of surfacing, not criticat yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> imnediately. Repairs must be completed uithin 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS (slope,setbacks,etc.): ,� � <br /> � <br /> POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): <br /> COMMENTS: <br /> � ' � <br /> Date o In pection e c System Znspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly� but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> tnformation. <br /> This report must be kept on the prE�nises with the system loc�tion and pumping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.