Laserfiche WebLink
: o� <br /> �. � <br /> ;- o o�,, <br /> �� � � � C ITY o� OIaONO <br /> ,�,,�a T,� ,�, <br /> "�, '�i; �. ';,�'r � l5, Municipal Offices <br /> /i.�:���.. �f�. � <br /> �,t � :��+. �;':�'' �.�;.�G Street Address: qSa-a4q-�16o 0 Mailing Address: <br /> �xEB�I�¢ 2750 Kelley Parkway P.O. Box 66 <br /> - Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: ��S � C�+'� �✓r- <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMIT'Y (1-3)_ � <br /> 1 "CODE SYSTEM" An LSTS which meets all the location,design and construc6on standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an icnminent threat to public health or safety. <br /> �l"NON-COMPLIANT SYSTBM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> ��or may not meet all the location,design,or construction stan�rds of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): 6 <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> USeptic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped �i'�—�� )• <br /> Make sure septic tanks are pumped throu�h manhole and not throu�h white inspection pipes. This ailows for the proper <br /> cleanin� Keep water softner and iron filter dischar�e out of septic svstem to prolong life of drainfield. Ask pumper to test <br /> alarm float to verify alarm is still workin�in your house The alarm warns owner that septaSe is about to backup into_basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"d�a.pipe)must be mstalled m each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION 8-10 : 71 <br /> Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: Q��'����t� -�S a�oc�— co�.,�1:a�fi ��� t�.vS'� 6� (CP�1c,c� �Y <br /> �a.=3� �-�e�o Q y�..�, 5���-i ��K S S�f�� Zo 0 5"- Ivi c eJ �c.,. ;�Spt��;F� <br /> �a�5 a� ��t��.,►�� . <br /> 6-Z� — oy �� <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> vote: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that d�is report does <br /> not guarantee or certify that an existing system witl continue to fimction properly. but is mercly an opinion of die adequacy of the system under current <br /> conditiuns based on the available intorniation. <br />