Laserfiche WebLink
SP TESTING INC. <br /> � Steven B.Schirmers—951 Katydid Lane NE-5t Mi�ael,MN 55376 <br /> CerL No 627—State License#394 — Phone 763-497-35b6— Fax 763-097-5011 <br /> www.sntestfn¢.wastewater(a�comcast net— schirmerswasbewater.com <br /> Octo6er 4, 2016 <br /> John Adams <br /> 4245 Chippewa Lane <br /> Medina, MN <br /> A Compliance inspection was completed for the existing on-slte sewage <br /> treatmen#system located on this property, The system consists of 2-1250 <br /> gallon septic tanks, 1-7250 gallo�pumping chamber 8 a pressurized mound <br /> system with a 10'x 68' rock bed built in 2001'for a 5 bedroom home.Soit <br /> boring #1 found mottled soll (redox features�at 2.3'fr�to the original soil. Soil <br /> boring #1 found the original soil at elev.91,4 8 the bottom of the rock bed at <br /> elev.92.21eaving .8'of sand b�low tfie rock bed S a 3.1'separafion from the <br /> bottom of the rock bed 8 redox features. Soil boring#2 found mottled soif at <br /> .S'into the original soil. Soil boring#2 found the original soil at elev. 90.5 8 <br /> the bottom of the rock bed at elev.92.5 feaving 2'of sand below the rock bed <br /> 8 a 2.8'separation from the bottom of tt�e rock bed 8 redox teatures. This <br /> system is classified as in compliance wfth Minnesota Chapter 7080 rules <br /> using the 15%reduction allowed. <br /> The tanks were pumped 8 certified by Elmer J. Peterson Co. <br /> Nothing other than gray water(laundry,showers etc.)hurr�an waste 8 toilet <br /> tlssue shouid be disposed of i�o the septic tanks. Garbage disposals are <br /> not recommended due to adding more s�lids&fine solids passing through <br /> into the system. Iron fllters are also not recommended 8 should be diverted <br /> out of the system. Exceasive amounts of soaps,aatlbacterial soaps, <br /> cleaning aeents,shower cleaners used every shower 8�chlorine agents may <br /> kill the bacteria you need living In the system. Additives are not <br /> recommended. Recommend to pump 8 clean you tanks through the manhole <br /> by a certified pumper every 2 years. Check with your pun�per to set up a <br /> schedule. <br /> Thfs certificate of compliance is no guarantee that this systetn will eontinue <br /> to function indefinitely. <br /> St�ven B. Schirmers <br />