Laserfiche WebLink
ON SITE SEWAGE TREATMENT <br />INSPECTION REPORT <br />ORONO <br />OWNER (Jac 11 <br />PERMIT NO.'S.DATES <br />DDRESS <br />QO <br />Oh the Sorth Shore of <br />Lake Minnetonka <br />POST OFFICE BOX 66 <br />1335 S. Brown Rd. <br />Crystal Bay. MN 55323 <br />4737357 <br />•47^5' *TT~, <br />CONTRACTORS 1 <br />□ 2 <br />City Ordinance No. 210 requires that each utsite sewage treatment system in Orono be inspected on a regular basis.'The on-si*c sewage <br />treatment system at the above address has been inspected and appears to fall into the category checked below. <br />(This is D an existing system ^^new construction) <br />Meets or exceeds current City standards m all respects relating to design, construction, and location. Ap(>ears to be operating <br />properly. <br />Docs not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, <br />located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major <br />upgrading of the system is required at this time. <br />Does not meet current City standards in many respects relating to design, construction, oi location. Appears to be operating <br />adequately at this time, but has a relatively high potential for future problems. No major upgrading o* system is required at <br />this time. <br />System ma\* or may not meet current City standards for design, construction or location, but is failing to properly treat and <br />dispose of tht current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters, or is <br />creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Insftector to discuss system repair/ <br />replacement procedures. If drainfield replacement is necessary, soil testing will usually be required, and a design and site plan <br />must be submitted for review. Your contractor must obtain a permit before work is started. <br />SYSTEM CONDITION ( C9 Checked items may require your action) <br />Tank ipspection indicates: <br />if Pumpout not needed at this time. <br />□ Solids accumulation in tanks indicates they should be pump* <br />ed out this year to help prevent future problems. <br />□ Solids accumulation in tanks is at a critical level. Tanks <br />should be pumped out as soon as possible. <br />D System is discharging to surface. Tanks must be pumped <br />within 48 hours to eliminate surface discharge. <br />□ Inspection risers missing-tanks could not be inspected. <br />Inspection risers (4“ dia. pipe) must be installed in each tank <br />at next pumpout. If tanks have not been pumped out within <br />the last three years, they should be pumped out now. <br />D l.nspettion pipe is located directly over lank baffle. (Does not <br />give accurate measurement of solids accumulation.) If tanks <br />have not been pumped out within the last three years, they <br />should be pumped out now. <br />Drai tfjjild inspection indicates: <br />^[Drainfield is dry, no surfacing evident. <br />G Some evidence of surfacing, not critical yet. <br />□ Drairfield is saturated and visibly discharging untieated <br />effluent to the surface. This condition may require replace­ <br />ment or additions to drainfield. Contact the City Inspector <br />immediately. Repairs must be completed within 90 days. <br />□ Drainfield extent and condition unknown. <br />SITE CHARACTERISTICS: <br />Limiting Site Factors <br />□ Slope <br />□ Soil <br />O High water table <br />□ Lot Sire <br />□ Lake, wetland, or stream <br />□ Drainage <br />Potential for System Failure <br />(depends on soil types, water <br />table^Md system condition) <br />H Low <br />G Medium <br />G High <br />G System is causing visible <br />Site Capabilities for <br />F uturcJE xpansion <br />IS^dequate <br />G Fair <br />G Poor <br />G Inadequate <br />COMMENTS J'C-WL Jt a. A <br />t surface ducharge. \ \ 1 \ <br />o a.(/atl&ioW ar <br />Date of Inspection 4Septic Syslem Inspector <br />Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that <br />this report does not guarantee or certify that an existing system will continue to function pro(>erlv . but is merely n. opinion of the adequacy <br />of the system under current conditions based on the available information. <br />This report must be kept on the premises with system location and pumping records. <br />WHITE COPY / Inspector s File GOLD COPY / Homrownei