Laserfiche WebLink
i O <br />. . ;�..:. CITY of ORONO <br />Munkipd OAkes <br />tined A&M. MWft Alms:; <br />2750 Kelley Parkway P.O. Box 66 <br />Orono, Mk 55356 Crystal Bay, MR 55323MO <br />Irmo <br />1_ <br />Owner: Address: 1000 Cox Tara Rd. <br />Permit N's: 8394 Da es: 9/18/94 Contractors: Reyes sxc. <br />(This is (x an existing system [ J :t(..w construction). <br />LY,STEM COMPLIANCE (1-3): 1 <br />UCode em: Meets or exceeds current City standards in all respects relating to design, <br />c <br />o <br />ns <br />t <br />ructston, and location. Appears to be operating properly. <br />2 Compliant System: Does not meet all current City standards for new construction, but in <br />most respects appears to be designed, located, and constructed in accordance with previous <br />codes and is functioning properly. <br />3 Non -Compliant System: System may or may not meet current City standards for design, <br />construction, or location, but is failing to properly treat and dispose of the current <br />input; and any system with less that three feet of vertical separation between the bottom <br />of the drainfield and the saturated soil level. <br />(The saturated soil level is (iCI or is not ( ) identified under this septic Wates. If the <br />saturated soil level is not identified, this classification is subject to revisica.) <br />K CONDITION (5-9): S <br />5 Pumpout not needed at this time. <br />Solids accumulation in tanks indicates they should be pumped out this fear. <br />7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br />8 Inspection risers missing -tanks could not be inspected. If tanks hal;. not been pumped out <br />within three years, they should be pumped out and risers installed n•o. <br />9 Inspection pipe is located over tank baffle -can not measure solids accumulation. If tanks <br />have not been pumped out within three years, they should be pumped out now. <br />10 One or more tanks are cesspools, which means the septic system is non-compliant. <br />(The tanks are 04 or are not I 1 Nater tight or the condition is I 1 Uaknown. If the tanks <br />are not confiraed to be watertight, this classification is subject to revision.) <br />DaATNFIRLD CONDITION (11-14): 11 <br />Drainfield is dry, no surfacing evident. <br />12 Sone evidence of surfacing, not critical yet. Repair is not required at this time. <br />13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br />Contact the City Inspector immediately. Repair must be completed within 90 days. <br />14 Drainfield extent and condition unknown. <br />POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.): low <br />COMMENTS: <br />Date ofInspection eft c System Inspector <br />Note: In the event that this inspection report is used to satisfy the requirements for a <br />transfer of property, this report dies not guarantee that an existing system will continue to <br />function properly, but indicates the operation of the system under current conditions. <br />Tallepboua (612) 473-7W 0 FAX M-010 <br />