My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1987-10-10 Septic System Design Specifications
Orono
>
Property Files
>
Street Address
>
C
>
Christine Drive
>
3505 Christine Drive - 05-117-23-12-0020
>
Septic
>
1987-10-10 Septic System Design Specifications
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2025 2:25:19 PM
Creation date
2/13/2025 2:18:51 PM
Metadata
Fields
Template:
x Address Old
House Number
3505
Street Name
Christine
Street Type
Drive
Address
3505 Christine Drive
PIN
0511723120020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S.P TESTING, INC. <br />961 KATYDID LANE <br />ST. MICHAEL, MN 55376 <br />497.3566 <br />STEVE SHIRMERS <br />November 10, 1987 <br />Tom Betz <br />Lot 3 of lot 41 <br />Auditor's Sub #203 <br />Stubbs Bay Road <br />Orono, Henn. Co., MN <br />This system is designed for a Type 1, four bedroom home and in accordance <br />with the Minnesota Pollution Control Agency standards WPC 40 and local <br />ordinances. <br />The soils on this site are typical of SCS soils mapped - :.+B - LeSueur loam. <br />A seasonally high water table was located at 16", 20", 22", 26", 5 280, <br />(mottling). Due to the seasonally high water table, a pre3surized mound <br />system will need to be installed. The bottom of the rock Iced must be lo- <br />cated at least 3' above the seasonally high water table. <br />The soils at a depth of 1B" have rzr^olation La`e aver%ying 6.1 min/inch <br />and are adequate for treating septic effi.-jnt. <br />A pumping chamber will need to be i.1stalled to lift the: `fluent to tt..? <br />treatment area. <br />The manifold and supply line pipe must ha -v:- uac:K drainage to the pumping <br />chamber. The distribution pipes shall hav,s their ends capped. Be sure <br />the rock and sand fill material are c ea,-. The sod layer below the <br />entire mounded area must be turned over, just break up the sod, be sure <br />not to over work. <br />The power supply and switches must be located outside the manhole and <br />pumping chamber in a weather proof enclosure. A warning device must be <br />installed with a light and sound device, this is in case of a pump failure. <br />(Mercury floats are a good method). <br />All neighboring wells are located more than 100' away from the proposed <br />treatment area. <br />Keep all heavy equipment off of the proposed treatment area before and <br />after construction as much as possible. The treatment area should be <br />marked off before construction. <br />With proper installation and maintenance, this system should have no <br />problem.in treating septic effluent effectively. <br />It is recommended that the septic tanks be pumped evr-r7 2 years. <br />Soil and PercoMtiow To.a��_ 1�iL� �_ _ <br />Septic System D filln Steven B. Schirmers <br />SBS/ds <br />
The URL can be used to link to this page
Your browser does not support the video tag.