1980-12-30 Septic System Site Evaluation
Orono
>
Property Files
>
Street Address
>
B
>
Brown Road South
>
430 Brown Road South - PID: 03-117-23-42-0011
>
Septic
>
1980-12-30 Septic System Site Evaluation
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/18/2024 11:07:13 AM
Creation date
9/18/2024 11:05:18 AM
Metadata
Fields
Template:
x Address Old
House Number
430
Street Name
Brown
Street Type
Road
Street Direction
South
Address
430 Brown Road South
PIN
0311723420011
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
■ <br />SI1T3 EVALUATION REPORT <br />RUXTON STRONG PROPERTY <br />IN THE S.E.Vc OP SEC. 3-117-23 <br />OROKO, MINNESOTA <br />12-30-00 <br />On Decenbor 12-ll|., I960 six percolation holes were tested <br />and 3 soil borings taken on each of 2 proposed lets on the Rux- <br />ton Strong property. I^ie percolation holes were dug 6 inches in <br />dicnetsr to a 42 inch depth v;hile the soil borings were dug 6 i <br />inches in diameter to the 4 foot depth and 3 inches in diameter <br />to the 0 foot depth, Thie percolation holes were dug with both <br />a power and hand operated auger v/hlle tho soil borings were dug <br />with tho hand operated bucket type augor. <br />Both lots are situated on top of a high wooded knob con <br />sisting of the Kilkenny loam soil series. Because of tho loc <br />ation the coil was verj dry nnd hard and thus v;as kept satura <br />ted for a long tine before testing. The average percolation <br />rates for tho two lots were 25».0 and 34.4 nlnutos per inch <br />v;hich vihen combined with the lack of a high water table ena <br />bles standard drainflold systems to bo construe*..! on each lot. <br />Because the whole area is relatively level it appears that <br />some typo of pumping system will have to bo used if full base <br />ments are to bo served. Additional cyston design information <br />viill bo needed once tho location and size of the houses to be <br />constructed ore Imovm. If any other infomatlon is needed be <br />fore that time, please contact me. <br />Sincerely, <br />PSRCOR, INC. <br />Mark S, Gronberg, Y <br />i. : <br />■ t <br />• t ■’ <br />* MAR2 7IS9I