My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1983 Subdivision Site Evaluation Report
Orono
>
Property Files
>
Street Address
>
A
>
Abingdon Way
>
2380 Abingdon Way - 03-117-23-23-0016
>
Land Use
>
1983 Subdivision Site Evaluation Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:35:30 PM
Creation date
2/1/2023 1:55:44 PM
Metadata
Fields
Template:
x Address Old
House Number
2380
Street Name
Abingdon
Street Type
Way
Address
2380 Abingdon Way
Document Type
Land Use
PIN
0311723230016
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SITE EVAIAJATION REPORT <br />FOR WILLOW PROPERTIES <br />( GARY PETEHSOK ) <br />OROKC, KINKESCTA <br />5-30-63 <br />On Kay U-30, I963 six percolation holes were tested on <br />each of 10 lots and 3 soil borings taken on each lot as well <br />in accordance with the provisions of Individual Sewage Sya- <br />ten Treatment Standards (WPC-I4.0) adopted in 1976 by the Kinn- <br />eaota Pollution Control Agency. In addition, other soil bor <br />ings were taken in lower areas to deteznnine the possibility <br />of obtaining more than 10 lots but water tables were found <br />to be very high and the soils were found to be very slowly <br />permeable. <br />According to the soils maps and the information we <br />found in the field, the higher areas had very good soils for <br />drainfields while the lower areas and swales had extremely <br />poor soils for drainfields. Thus, we tended to stick to the <br />higher areas while still leaving room for ample building <br />sites. However, once houses are proposed to be constructed <br />it mighc be desired to shift some of the drainfield areas. <br />Then n w testing would be required and it would be advise- <br />able to keep ts high up on the kncl-r as was previously tes <br />ted. <br />Each site tested would be acceptable for either a stan <br />dard or shallow trench drainfield system and is noted on the <br />attached drawing. It also might be necessary to use inter <br />ceptor drains to divert runoff water but this would be men-’ <br />tioned in the system design for the individual houses once <br />they are ready for construction. If any additional informa <br />tion is needed, please contact me. <br />Sincerely, <br />PERCOR, IKC. <br />^Mark S. Gronberg, T.E.
The URL can be used to link to this page