My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1985 Septic System Design Specs
Orono
>
Property Files
>
Street Address
>
A
>
Abingdon Way
>
2290 Abingdon Way - 03-117-23-23-0010
>
Septic
>
1985 Septic System Design Specs
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:35:21 PM
Creation date
2/1/2023 11:19:27 AM
Metadata
Fields
Template:
x Address Old
House Number
2290
Street Name
Abingdon
Street Type
Way
Address
2290 Abingdon Way
Document Type
Septic
PIN
0311723230010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM DESIGN <br />FOR EIDEN CONSTRUCTION <br />OF LOT 8, BLOCK I, ABINGDON GLEN <br />ORONO, MINNESOTA <br />10-24-85 <br />1. Percolation Rate, Type of System. <br />10.7 minutes per inch for the primary site (holes 1-4). Shallow Trench System. <br />2. Proposed Flow Rate. <br />6 bedrooms @ 150 G.P.D. = 900 G.P.D. <br />3. Soil Treatment Area Required. <br />i,67 percolation rate factor x 900 G.P.D. = 1500 Sq. Ft. <br />4. Size and Number of Trenches. <br />5 trenches 3 feet wide and 100 feet long =1500 Sq. Ft. These trenches would <br />be spaced 7.5 feet apart center to center and be no deeper than 1.5 feet deep <br />in the natural soil. <br />5. Drainfield Rock Needed. <br />56 cubic yds. of rock is needed to have 6 inches under and 2 inches over a 4 <br />inch distribution pipe. <br />6. Septic Tanks. <br />Two septic tanks each of 1000 gallons are needed. In addition, if the house <br />is not kept high enough, a third pumping tank and pump would be needed to <br />reach the drainfield area. <br />7. Additional Information. <br />Grading must be done to divert runoff water away from the drainfield trenches. <br />The use of an interceptor draintile could also be used. All construction traf <br />fic must be kept off both drainfield sites and no grading is allowable in ei <br />ther area. All construction and materials must adhere to the provisions of <br />the city of Orono. <br />If there are any other questions, please contact me. <br />Sincerely, <br />PERCOR, INC. <br />Mark S. Gronberg, P.C. <br />PCA certified
The URL can be used to link to this page