Laserfiche WebLink
*-V <br />Task # 54787 <br />Date Called in 07/26/2021 <br />Date Scheduled I 07 28 202 9:30 AM <br />City Of Orono <br />Point of Sale Sanitary Sewer Service I&I Compliance Inspection Form <br />Property Address: 11205 Shoreline Dr <br />PID; 0211723430015 <br />Owner Information <br />Name: <br />Mary Jackley <br />Mailing Address: <br />(if different from <br />Property) <br />,�icense number: <br />Phone: <br />612-968-2073 1 Email: madack8809@gmail.com <br />Ins ect r Information <br />Name: <br />Standard <br />Company/ Organization <br />,�icense number: <br />Roof Drains <br />Phone: <br />Email: <br />Inspection <br />System <br />Standard <br />Pass <br />Fail <br />Roof Drains <br />Roof drains and leaders Roof drains should not be connected to the sanitary <br />Name: <br />sewer but should discharge to the ground outside of a building. If the roof <br />drains are connected to the sanitary sewer, disconnect them, plug any open <br />connections to the sanitary sewer using a non -shrink permanent material, and <br />redirect the roof drains onto the ground outside the building. <br />Foundation <br />Foundation drains are underground pipes that collect storm water from <br />Drains <br />Found the base of a building and into a sump basket, where it is then <br />1 <br />pumped outside of the building. Foundation drains should not be connected <br />v <br />to the sanitary sewer. <br />Sump Pumps <br />Sump pumps are designed to capture surface or ground water that enters <br />basements or crawl spaces and pump it away from the house. The basic sump <br />system includes drain tile, a sump pit, a sump pump, a float or switch, and a <br />drain line. Sump pumps should not be connected to the sanitary sewer. <br />Sewer Service <br />Line <br />Sanitary Sewer hiflow & Infiltration (I11) Compliance Inspection Sanitary <br />Sewer Lines. All sanitary sewer lines serving Property, from the house to the <br />main line, shall be in a safe and fmictional condition and shall be free from all <br />leaks, failures including but not limited to partially collapsed sections or tree <br />lf// <br />root intrusion. The sanitary sewer lines shall meet the City Code standards and <br />specifications.(Details on back of this sheet) <br />Notes: <br />��S <br />City Review <br />Inspectors Signature: <br />Date: <br />Owners signature: <br />I Date: <br />City Review <br />ompliant <br />V Corrective Action Required <br />Certificate of Compliance Ex fres: WM3 <br />Corrective Action Due by: <br />Date: <br />3 .91 <br />Si ature: <br />Name: <br />Service Line Inspection Details <br />C <br />vel yI�1, "t 5` v k <br />Rf 6 (11 L-1 <br />