Laserfiche WebLink
SEPTIC SYSTEM INVENTORY <br /> • <br /> Address: 365 Willow Dr. N. PID: 33-118-23 41 0001 <br /> Building Type residence BRs Install'd for: 2 In Musa: No <br /> Permit#: 1369 Date of Permit: 10/27/88 Installer: E. J. Peterson, Jerry John <br /> System Type: standard trench Experimental: no Tank Filter: <br /> SYSTEM CONDITION <br /> Conformity: 3 Tank Condition: 6 DF condition: 11 Failure Pot: low <br /> SEPTIC TANKS <br /> Material: concrete block&pr Capacity: 1200, 800, 1000 <br /> Setback to Bldg: 30 Cesspool: unknown <br /> DRAINFIELD <br /> Length of Lines: 200 #Lines: 4 Trench Width: 3 <br /> Treatment Area: 600 Type of Filter: rock Soil Boring: yes <br /> Tile Size: 4 Under Tile: 6 Perc Rate: 3.9 <br /> Setback DF-Bldg: 50 DF Ht above Wt: 0.2 <br /> Soil Type: loam Limitations: water table <br /> WELL DATA <br /> Setbacks - Well-Tanks: 60 Well-DF: 75 Report in File yes <br /> Pump Type: subm. Depth: 230 Diameter: 4 Method: drilled <br /> INSPECTION RECORD PUMPOUT RECORD <br /> DATE DESCRIPTION COMPLIANCE DATE GALLONS <br /> 5/11/79 no surfacing s 11/15/78 1500 <br /> 8/17/81 no surfacing 2 10/18/85 1800 <br /> 8/28/86 owner driving over tanks-no surfacing 2 9/1/88 1500 <br /> 8/4/88 owner driving over tanks-no surfacing 2 <br /> 11/1/88 added pump tank(1000 gal.),DF (600 sfll <br /> 10/23/91 no surfacing-pump tanks 1 <br /> 11/10/93 no surfacing-pump tanks 1 <br /> 10/26/95 no surfacing-pump tanks 1 <br /> 6/1/98 non-compliant-repair by 12/31/2008 3 <br /> 8/28/00 non-compliant, repair by 12/31/2010, pu non-compliant <br />