Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
SEPTIC SYSTEM INVENTORY <br /> Addr: 340 Westlake St . PID: 05-117-23 23 0013 <br /> Building Type : residence # BRs/GPD: 2 # Systems/units : 1/i <br /> Permit No: 5627 Date of Permit : 7/5/79 Installer: R. W. Wenner <br /> System Type : wide trench Appliances : <br /> SYSTEM CONDITION <br /> Conformity: 2 Tank Condition: 9 DF condition: 11 <br /> Failure Pot : medium <br /> SEPTIC TANKS <br /> Material : precast concrete Capacity: 800 <br /> Setback to Bldg: 10 <br /> DRAINFIELD <br /> Length of Lines : 83 No. Lines : 3 Trench Width: 4 . 5 <br /> Treatment Area: 375 Type of Filter: rock <br /> Tile Size : 4 Under Tile : 12 Perc Rate mn/in: <br /> Setback DF-Bldg: 20 DF Ht above WT: <br /> Soil Type : clay loam Limitations : <br /> WELL DATA <br /> Setbacks - Well-Tanks : 55 Well-DF: 65 <br /> Report in File? : Pump Type : <br /> Depth: Diameter: Method: <br /> INSPECTION RECORD PUMPOUT RECORD <br /> Date Compliance Date Gallons <br /> 7/12/79 replacement installation 2 11/3/88 500 <br /> 7/16/84 no surfacing-owner says sump to septic 2 6/5/95 500 <br /> 9/23/86 no surfacing 2 <br /> 8/2/90 no surfacing 2 <br /> 6/7/91 no surfacing-pump tanks 2 <br />