Laserfiche WebLink
SEPTIC SYSTEM INVENTORY <br /> Address: 2275 Webber Hills Rd. PID: 03-117-23 33 0004 <br /> Building Type residence BRs Install'd for: 3 In Musa: Yes <br /> Permit#: 6839 Date of Permit: 10/6/82 Installer: Widmer Bros., E. J. Peter <br /> System Type: standard trench Experimental: no Tank Filter: <br /> SYSTEM CONDITION <br /> Conformity: 3 Tank Condition: 6 DF condition: 11 Failure Pot: medium <br /> SEPTIC TANKS <br /> Material: concrete block Capacity: 1000, 750 <br /> Setback to Bldg: 13 Cesspool: <br /> DRAINFIELD <br /> Length of Lines: 200 #Lines: 2 Trench Width: 2.5 <br /> Treatment Area: 1100 Type of Filter: rock Soil Boring: no <br /> Tile Size: 4 Under Tile: 6 Perc Rate: <br /> Setback DF-Bldg: 35 DF Ht above Wt: 0.8 <br /> Soil Type: loam, clay loam Limitations: water table <br /> WELL DATA <br /> Setbacks - Well-Tanks: 50 Well-DF: 75 Report in File yes <br /> Pump Type: subm. Depth: 198 Diameter: 4 Method: drilled <br /> INSPECTION RECORD PUMPOUT RECORD <br /> DATE DESCRIPTION COMPLIANCE DATE GALLONS <br /> 7/11/78 no surfacing s 7/1/82 1750 <br /> 7/2/82 DF surfacing 4 10/1/85 1500 <br /> 10/26/82 added DF (600 sf) 1 9/1/86 1800 <br /> 6/13/84 no surfacing 1 9/1/87 1800 <br /> 9/20/85 no surfacing 1 10/1/88 1800 <br /> 8/4/87 no surfacing 1 10/1/89 1800 <br /> 6/26/90 no surfacing-pump tanks 1 1/1/91 2000 <br /> 7/20/92 no surfacing 1 3/1/92 2000 <br /> 10/14/94 no surfacing 1 2/1/93 1800 <br /> 7/31/96 non-compliant,repair by 12/31/2006,pum3 6/6/94 1000 <br /> 11/3/97 non-compliant-repair by 12/31/2006 3 5/7/97 1500 <br /> 11/07/02 non-compliant,replace by 12/31/2007 non-compliant 11/3/98 1500 <br /> to-XS--oLt 60/LA e--r 34 L2,71-0/-0/ 8/09/01 1500 <br /> AA- (-) <br />