Laserfiche WebLink
7'71--- - <br /> --6.1V <br /> -...--- s e . <br /> 70' -' -v <br /> i „ 0 <br /> 1;\'''' <br /> ogw° Fire Inspection Report <br /> Property Name ,.e v v, c e4 d Date /3 oi 7 7 <br /> Property Address 7-19 0 La. t-6 cey &?✓a Occ. Class. >3 -- 3 <br /> Owner Name Phone# <br /> Contact Person Phone# <br /> Const. Type IV—. Const. Year i 9 479 Addit. Year <br /> N Y NA 1.Exterior N Y NA N Y NA g.Sprinkler Systems <br /> ❑ ❑ ❑a.Fire Lanes marked/unobstructed 0.0 De.Storage maintained 2'below ceiling 0 0 ❑a.Adequate coverage <br /> ❑ ❑ 0 b.Address Visible (unsprinklered) 0 ❑ 0 b.Controls readily accessible <br /> ❑, ❑c. Fire hydrant(s)accessible 0 El ❑f. Storage maintained 18"below 0 0 ❑c.Valves locked open or supervised <br /> ❑ ❑d.Combustible accumulation acceptable sprinkler heads 0 0 0 d. Properly serviced <br /> ❑ 0 ❑e.Gas Meter/piping protected 0 CS ❑g.Aisles maintained-44"min. 0 0 ❑e. Heads in good condition <br /> o j, ❑f. F.D.connections visible/good ❑ NI ❑h.Rubbish,oily rags,waste material 0 0 ❑f. Wrench/spare heads present <br /> conditions properly stored <br /> 10.Fire Alarm Equipment <br /> 2.Exit Features 5.Flammable/Comb.Liquids 0 ® 0 a.Detectors(smoke,heat)properly <br /> ❑ in. ❑a.Adequate number of exits 0 0 ❑a.Proper quantities installed <br /> ❑ 0 ❑b. Exits,aisles and corridors free of 0 0 ®b.Proper storage/dispensing 0 in 0 b.Pull stations properly installed <br /> obstructions 0 0 Elc. No sources of ignition 0 0 ❑c.Detectors needed <br /> ❑ op ❑c. Exits openable from inside 0 0 kid.Adequate ventilation 0 0 Ed. Properly serviced/maintained <br /> ❑ Li 0 d. Exit hardware present and operational 0 0 (fie. Proper electrical equipment 0 0 ge.Tests/drills conducted <br /> ❑ r❑ 0 e.Exit signs present <br /> ❑ 0 0 f. Exit corridors protected 6.Utility.Mechanical,HVAC Equip, 11.Other Fire Protection Equip, <br /> ❑ 0 0 g.Emergency lighting present and 0 0 ❑a. Relief valve present on boilers and 0 0 Oa.Standpipes needed <br /> operational water heaters 0 ❑ b.Standpipe/hose in good condition <br /> ❑ 0 ❑h.Occupant load posted and maintained 0 ,® ❑b.Shut off valve present on gas 0 0 c.Adequate coverage <br /> ❑ 0 0 i. Interior finish acceptable appliances 0 ❑ d. Hood system-fuel shutoff present <br /> 0 ►= ❑c.Adequate clearances between 0 0 e. Properly serviced/maintained <br /> 3.Construction Features combustibles and appliances <br /> ❑ 0 Da. Fire separations present and 0 1E1 ❑d.Clean ducts and filters 12.Electrical <br /> maintained 0 5 ❑a.Appliances/fixtures in good condition <br /> ❑ 0 0 b.Structural elements intact 7.Fire Extinguishers 0 ® 0 b.Overcurrent protection present <br /> ❑ 0 ❑c.Rated fire doors present and 0 ❑a.Readily accessible/suitable location 0 fg ❑c. Proper use of wiring,connections, <br /> operational(closing/latching) 0 rEl ❑b. Proper number and type equipment <br /> ❑ 0 0 d.Vertical openings acceptable 0 ra Dc. Properly serviced/maintained 0 ® 0 d. Extension cords not used in place of <br /> fixed wiring <br /> 4.Storage 8,Hazardous Materials 0 Ig 0 e.30"clear access to panels provided <br /> ❑ 15 0 a.Storage neat and orderly 0 0 ❑a. Proper quantities <br /> ❑ 0 0 b. No combustible storage in boiler or 0 0 Ob. Proper Storage/Dispensing 13.Other: <br /> mechanical rooms 0 0 ❑c. Proper Separation/Compatability 0 0 0 kit M 130N- <br /> ❑ ❑J]c.No combustible storage in unprotected 0 0 Od. Marking/Identification present 0 0 0 <br /> attics 0 0 De.Compressed gas cylinders secured 0 ❑❑ 0 <br /> El ❑ ❑d. No combustible storage under <br /> 0 <br /> unprotected stairways <br /> Persons on Inspection: <br /> FOR FURTHER ASSISTANCE, PLEASE CONTACT INSPECTOR NAMED BELOW. <br /> 011, <br /> Owner/Re �'J`� `"_ ! Inspector: <br /> P ISIanaarei IS,gnaiurel (Phone) <br />