My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017 SWPPP 4 of 4
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
2465 North Shore Drive - 09-117-23-44-0012
>
Survey
>
2017 SWPPP 4 of 4
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:51:44 PM
Creation date
1/9/2020 9:25:29 AM
Metadata
Fields
Template:
x Address Old
House Number
2465
Street Name
North Shore
Street Type
Drive
Address
2465 North Shore Dr
Document Type
Survey
PIN
0911723440012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIGURE 1 TYPICAL INSTALLATION FOR SILT FENCE <br />TABLE 1 MAXIMUM SLOPE LENGTH AND SLOPE FOR WHICH SILT FENCE IS APPLICABLE <br />WIRE MESH REINFORCEMENT, <br />BY CALCULATION <br />BY ACCEPTED <br />DESIGN PRACTICES <br />ATTACH FABRIC TO WIRE <br />PERCENT <br />SILT FENCE STORAGE <br />EQUALES 2 FT FOR A <br />100 -YEAR EVENT <br />SILT FENCE STORAGE EQUALS 2 FT <br />FOR A 2 -YEAR EVENT OR 3 FT FOR <br />A 100 -YEAR EVENT <br />MESH WITH HOG RINGS, PER <br />100:1 <br />METAL (OR WOOD) <br />400 FT <br />MNDOT SPEC. SECTION 3886 <br />100 FT <br />50:1 <br />2% <br />B1.SILT <br />450 FT <br />POST OR STAKE <br />25:1 <br />FENCE <br />100 FT <br />225 FT <br />75 FT <br />FABRIC <br />5% <br />80 FT <br />180 FT <br />FABRIC ANCHORAGE <br />DESIGN RECOMMENDATIONS <br />6% <br />67 FT <br />TRENCH BACKFILL <br />50 FT <br />12.5:1 <br />8% <br />WITH TAMPED 1. <br />SILT FENCES SHOULD BE INSTALLED ON <br />50 FT <br />10:1 <br />NATURAL SOIL <br />THE CONTOUR (AS OPPOSED TO UP AND <br />-- <br />50-25 FT <br />5:1 <br />DOWN A HILL) AND CONSTRUCTED SO <br />DIRECTION OF <br />45 FT <br />25-15 FT <br />THAT FLOW CANNOT BYPASS THE ENDS. <br />RUNOFF FLOW <br />16 FT <br />36 FT <br />15 FT <br />3:1 <br />33% <br />12 FT <br />27 FT <br />15 FT <br />2:1 <br />50% <br />8 FT <br />77 q 1= 2. <br />ENSURE THAT THE DRAINAGE AREA IS NO <br />11 —I I —111-111-11 <br />PLAN <br />VIEW <br />—11 <br />GREATER THAN 1/4 ACRE PER 100 FT OF FENCE. <br />�_MAKE <br />= <br />THE FENCE STABLE FOR THE <br />3. <br />10 -YEAR PEAK STORM RUNOFF. <br />— <br />MIN <br />WHERE ALL RUNOFF IS TO BE STORED <br />NATURAL SOIL _I <br />1= 4. <br />BEHIND THE SILT FENCE, ENSURE THAT <br />THE MAXIMUM SLOPE LENGTH BEHIND <br />NOTE: SILT FENCE SHALL FOLLOW <br />THE FENCE DOES NOT EXCEED THE <br />MNDOT SPEC. SECTION 3886. <br />SPECIFICATIONS SHOWN IN TABLE 1. <br />FIGURE 1 TYPICAL INSTALLATION FOR SILT FENCE <br />TABLE 1 MAXIMUM SLOPE LENGTH AND SLOPE FOR WHICH SILT FENCE IS APPLICABLE <br />HEAVY DUTY SILT FENCE <br />NO SCALE <br />EXTEND MATERIAL — <br />ABOUT 40" ON TOP OF <br />THE GROUND AND <br />RANDOMLY INSERT <br />STAPLES THROUGH <br />THE MATERIAL ABOUT <br />20" APART <br />STAPLES AT 3' O.C. <br />STAPLES MUST BE <br />INSERTED THROUGH <br />OVERLAP MATERIAL <br />TRANSVERSE SEAM <br />BLANKET MATERIAL MUST <br />OVERLAP AT LEAST 6" AND <br />STAPLES INSERTED <br />THROUGH BOTH FABRICS AT <br />A MAXIMUM SPACING OF 20" <br />APART <br />LONGITUDINAL SEAM / / / / / AT END OF SLOPE <br />BLANKET MATERIAL MUST / SECURE BLANKET <br />OVERLAP AT LEAST 6" AND MATERIAL BY INSERTING <br />STAPLES ABOUT 20" <br />STAPLES INSERTED <br />THROUGH BOTH FABRICS AT APART THROUGH THEFABRIC <br />A MAXIMUM SPACING OF 40" <br />APART <br />NOTES: <br />1.EROSION CONTROL BLANKET TO BE CATEGORY 4 -COCONUT 2S FOR SLOPES GREATER THAN <br />5:1 AND SIDES AND BOTTOM OF ALL DRAINAGE SWALES AND PONDING AREAS AND <br />CATEGORY 2 -STRAW 2S FOR ALL SLOPES LESS THAN 5:1 PER MNDOT SPEC. SECTION <br />3885. <br />2•INSTALL PER MNDOT SPEC. SECTION 2575 <br />EROSION CONTROL BLANKET <br />NOTES: <br />1) ALL TREE PROTECTION FENCING AND EROSION CONTROL FENCING SHALL BE INSTALLED <br />ACCORDING TO THE PLANS PRIOR TO ANY DEMOLITION. AFTER DEMOLITION OR AS NECESSARY, <br />TREE PROTECTION FENCING MAY BE RELOCATED WITH APPROVAL FROM THE LANDSCAPE <br />ARCHITECT. ALL TREE PROTECTION FENCING AND EROSION CONTROL DEVICES SHALL BE <br />MAINTAINED FOR THE DURATION OF THE CONSTRUCTION PERIOD. <br />"—" T kCTOR SHALL NOT STORE ANY MATERIALS OR PARK ANY VEHICLES IN TREE PROTECTION <br />:iE FENCE SHALL PREVENT TRAFFIC MOVEMENT AND THE PLACEMENT OF TEMPORARY <br />S, EQUIPMENT, STOCKPILES AND SUPPLIES FROM HARMING VEGETATION WITHIN THE <br />'PROTECTION. <br />iNTRACTOR SHALL CLEANLY CUT ALL ROOTS EXPOSED BY GRADING AS DIRECTED BY <br />>SCAPE ARCHITECT. <br />iNTRACTOR SHALL USE DESIGNATED CONSTRUCTION ENTRANCES AND STAGING AREAS. <br />— 6' MAX --4 <br />?LINE <br />TREE PROTECTION FENCING <br />DRIPLINE <br />6' <br />FROM oRIPL jNE <br />NO SCALE <br />N z <br />FLOTATION <br />SEGMENT <br />WATER <br />SURFACE <br />FILTER CLOTH <br />SKIRT (DEPTH <br />VARIES) <br />BALLAST <br />CHAIN <br />CHANNEL <br />BOTTOM <br />NO SCALE <br />2" WASHED COARSE <br />AGGREGATE 12" <br />THICK MINIMUM WITH C0 O C <br />GEOTEXTILE 0 000 o° <br />UNDERLAYMENT <br />GRAVEL CONSTRUCTION ENTRANCE <br />INSERT <br />kBSORBENT PILLOW SHALL <br />'LACED IN THE POUCH ON <br />BOTTOM. ATTACH PILLOW <br />'ETHER LOOP <br />DUMPING STRAPS <br />1. OIL ABSORBENT PILLOW SHALL BE REMOVED AND REPLACED WHEN NEAR <br />SATURATION. <br />2. USE DANDY® BAG II AS MANUFACTURED BY DANDY® PRODUCTS, INC. <br />3. AN EQUIVALENT CATCHBASIN EROSION CONTROL INSERT METHOD OR PRODUCT MAY <br />BE USED WITH PRIOR APPROVAL FROM ENGINEER. <br />CATCH BASIN INSERT <br />UNIVERSAL CONNECTOR <br />- TOP TENSION CABLE <br />FLOTATION SEGMENT <br />FFOLD JOINT FOR STORAGE <br />&-- TOP LOAD LINE <br />FILTER CLOTH SKIRT <br />(DEPTH VARIES) <br />BALLAST CHAIN <br />AND LOAD LINE <br />SKIRT CONNECT — <br />GROMMETS <br />FLOATING SILT CURTAIN <br />NO SCALE <br />NO SCALE <br />10' MIN LENGTH <br />BY CALCULATION <br />BY CALCULATION <br />BY ACCEPTED <br />DESIGN PRACTICES <br />SLOPE <br />H:V <br />PERCENT <br />SILT FENCE STORAGE <br />EQUALES 2 FT FOR A <br />100 -YEAR EVENT <br />SILT FENCE STORAGE EQUALS 2 FT <br />FOR A 2 -YEAR EVENT OR 3 FT FOR <br />A 100 -YEAR EVENT <br />MAXIMUM SLOPE <br />LENGTH <br />100:1 <br />1% <br />400 FT <br />900 FT <br />100 FT <br />50:1 <br />2% <br />200 FT <br />450 FT <br />75 FT <br />25:1 <br />4% <br />100 FT <br />225 FT <br />75 FT <br />20:1 <br />5% <br />80 FT <br />180 FT <br />75-50 FT <br />17:1 <br />6% <br />67 FT <br />150 FT <br />50 FT <br />12.5:1 <br />8% <br />50 FT <br />112 FT <br />50 FT <br />10:1 <br />10% <br />40 FT <br />90 FT <br />50-25 FT <br />5:1 <br />20% <br />20 FT <br />45 FT <br />25-15 FT <br />4:1 <br />25% <br />16 FT <br />36 FT <br />15 FT <br />3:1 <br />33% <br />12 FT <br />27 FT <br />15 FT <br />2:1 <br />50% <br />8 FT <br />18 FT <br />15 ITT <br />HEAVY DUTY SILT FENCE <br />NO SCALE <br />EXTEND MATERIAL — <br />ABOUT 40" ON TOP OF <br />THE GROUND AND <br />RANDOMLY INSERT <br />STAPLES THROUGH <br />THE MATERIAL ABOUT <br />20" APART <br />STAPLES AT 3' O.C. <br />STAPLES MUST BE <br />INSERTED THROUGH <br />OVERLAP MATERIAL <br />TRANSVERSE SEAM <br />BLANKET MATERIAL MUST <br />OVERLAP AT LEAST 6" AND <br />STAPLES INSERTED <br />THROUGH BOTH FABRICS AT <br />A MAXIMUM SPACING OF 20" <br />APART <br />LONGITUDINAL SEAM / / / / / AT END OF SLOPE <br />BLANKET MATERIAL MUST / SECURE BLANKET <br />OVERLAP AT LEAST 6" AND MATERIAL BY INSERTING <br />STAPLES ABOUT 20" <br />STAPLES INSERTED <br />THROUGH BOTH FABRICS AT APART THROUGH THEFABRIC <br />A MAXIMUM SPACING OF 40" <br />APART <br />NOTES: <br />1.EROSION CONTROL BLANKET TO BE CATEGORY 4 -COCONUT 2S FOR SLOPES GREATER THAN <br />5:1 AND SIDES AND BOTTOM OF ALL DRAINAGE SWALES AND PONDING AREAS AND <br />CATEGORY 2 -STRAW 2S FOR ALL SLOPES LESS THAN 5:1 PER MNDOT SPEC. SECTION <br />3885. <br />2•INSTALL PER MNDOT SPEC. SECTION 2575 <br />EROSION CONTROL BLANKET <br />NOTES: <br />1) ALL TREE PROTECTION FENCING AND EROSION CONTROL FENCING SHALL BE INSTALLED <br />ACCORDING TO THE PLANS PRIOR TO ANY DEMOLITION. AFTER DEMOLITION OR AS NECESSARY, <br />TREE PROTECTION FENCING MAY BE RELOCATED WITH APPROVAL FROM THE LANDSCAPE <br />ARCHITECT. ALL TREE PROTECTION FENCING AND EROSION CONTROL DEVICES SHALL BE <br />MAINTAINED FOR THE DURATION OF THE CONSTRUCTION PERIOD. <br />"—" T kCTOR SHALL NOT STORE ANY MATERIALS OR PARK ANY VEHICLES IN TREE PROTECTION <br />:iE FENCE SHALL PREVENT TRAFFIC MOVEMENT AND THE PLACEMENT OF TEMPORARY <br />S, EQUIPMENT, STOCKPILES AND SUPPLIES FROM HARMING VEGETATION WITHIN THE <br />'PROTECTION. <br />iNTRACTOR SHALL CLEANLY CUT ALL ROOTS EXPOSED BY GRADING AS DIRECTED BY <br />>SCAPE ARCHITECT. <br />iNTRACTOR SHALL USE DESIGNATED CONSTRUCTION ENTRANCES AND STAGING AREAS. <br />— 6' MAX --4 <br />?LINE <br />TREE PROTECTION FENCING <br />DRIPLINE <br />6' <br />FROM oRIPL jNE <br />NO SCALE <br />N z <br />FLOTATION <br />SEGMENT <br />WATER <br />SURFACE <br />FILTER CLOTH <br />SKIRT (DEPTH <br />VARIES) <br />BALLAST <br />CHAIN <br />CHANNEL <br />BOTTOM <br />NO SCALE <br />2" WASHED COARSE <br />AGGREGATE 12" <br />THICK MINIMUM WITH C0 O C <br />GEOTEXTILE 0 000 o° <br />UNDERLAYMENT <br />GRAVEL CONSTRUCTION ENTRANCE <br />INSERT <br />kBSORBENT PILLOW SHALL <br />'LACED IN THE POUCH ON <br />BOTTOM. ATTACH PILLOW <br />'ETHER LOOP <br />DUMPING STRAPS <br />1. OIL ABSORBENT PILLOW SHALL BE REMOVED AND REPLACED WHEN NEAR <br />SATURATION. <br />2. USE DANDY® BAG II AS MANUFACTURED BY DANDY® PRODUCTS, INC. <br />3. AN EQUIVALENT CATCHBASIN EROSION CONTROL INSERT METHOD OR PRODUCT MAY <br />BE USED WITH PRIOR APPROVAL FROM ENGINEER. <br />CATCH BASIN INSERT <br />UNIVERSAL CONNECTOR <br />- TOP TENSION CABLE <br />FLOTATION SEGMENT <br />FFOLD JOINT FOR STORAGE <br />&-- TOP LOAD LINE <br />FILTER CLOTH SKIRT <br />(DEPTH VARIES) <br />BALLAST CHAIN <br />AND LOAD LINE <br />SKIRT CONNECT — <br />GROMMETS <br />FLOATING SILT CURTAIN <br />NO SCALE <br />NO SCALE <br />10' MIN LENGTH <br />SHORELINE ANCHORING <br />INSTALL SHREDDED HARDWOOD <br />COIR LOG 6"-7" <br />MULCH (MNDOT TYPE 6). <br />MINIMUM <br />EQUIVALENT MATERIAL MAY BE <br />DIAMETER <br />SUBSTITUTED AT THE DISCRETION <br />OF THE ENGINEER. <br />STAKE DRIVEN <br />THROUGH LOG <br />1/3 OF LOG <br />MESH <br />2/3 OF LOG <br />SHORELINE ANCHORING <br />SHORE <br />ANCHOR <br />SHORELINE <br />DISTURBED <br />GROUND/WORK <br />ZONE <br />I <br />CLEAR <br />WATER <br />W <br />ITURBIDITY <br />CURTAIN <br />Q <br />0 <br />SHORE <br />CHANNEL <br />ANCHOR <br />ANCHOR <br />PLAN <br />VIEW <br />NO SCALE <br />COIR LOG <br />NO SCALE <br />2465 <br />Remodel <br />2465 North Shore Drive <br />Orono, MN <br />Stormwater <br />Pollution <br />Prevention <br />Details <br />
The URL can be used to link to this page
Your browser does not support the video tag.