Laserfiche WebLink
NOTE: THE EXISTING ROCKBED IS TO BE <br />EXTENDED 22' TO THE NORTH. THE <br />EXISTING NORTHERLY SIDESLOPE OF THE <br />MOUND IS TO BE REMOVED INCLUDING <br />THE SAND IN THE AREA OF THE <br />PROPOSED ABSORPTION AREA. THE <br />ABSORPTION AREA IS TO BE SCARIFIED <br />AND WASHED MOUND SAND IS TO BE <br />FILLED TO THE BOTTOM THE ROCKBED. <br />THE REMAINDER OF THE PROPOSED <br />MOUND ADDITION IS TO BE <br />CONSTRUCTED AS NORMAL. <br />9 <br />MILLER'S .SEWAGE TREATMENT SOLUTIONS <br />A division of WRM Services Inc. <br />PO BOX 458 Kimball, MN 55353 <br />(320) 398-2705 cell (320) 980-1737 <br />21.2' <br />-� 05 -- <br />PROPERTY LOCATION <br />Lot 1, Block 1, Burgers Bayside, <br />Second Addition„ Hennepin County, <br />Minnesota. <br />pid#517-117-23 21 0019 <br />Septic System Site Plan <br />DATE JOB NO. SCALE <br />2127106 2006-28 Is2(} <br />PREPARED FOR: <br />Streeter <br />[Fullerton <br />APPROXIMATE MOUND ADDITION QUANTITIES <br />Rock Quantity = 8.1 f yards <br />Sand Quantity = 65-- yds. <br />Loamy Sand Quantity = 8+ yds. <br />Top Soil Quantity = 25-± yds. <br />*Quantities are approximate <br />and do not include waste <br />Notes <br />Avoid compaction of mound area before, during and after <br />construction. <br />Verify before construction that no wells are within 50 feet <br />of the proposed or existing septic tank. <br />Verify before construction that no shallow wells are within 100 feet, <br />or any deep wells within 50 feet of proposed treatment area. <br />All materials used for construction must meet or exceed the <br />M.P.C.A. Chapter 7080 requirements. <br />Divert surface drainage away or around the septic area. <br />All dimensions, quantities and elevation shown on plan are approximate. <br />I hereby certify that this site plan was prepared by me or <br />& Associates under my direca super 'ion. <br />Res.I / Bernie Miller Miller D.R. . M. P. C. A. License # 1921 <br />LEGEND <br />denotes <br />well location <br />O <br />denotes <br />perc test location <br />0 <br />denotes <br />soil .boring location <br />( 97*8 <br />) denotes proposed elev. <br />97*8 <br />denotes <br />existing elev. <br />-0 <br />denotes <br />surface drainage <br />Notes <br />Avoid compaction of mound area before, during and after <br />construction. <br />Verify before construction that no wells are within 50 feet <br />of the proposed or existing septic tank. <br />Verify before construction that no shallow wells are within 100 feet, <br />or any deep wells within 50 feet of proposed treatment area. <br />All materials used for construction must meet or exceed the <br />M.P.C.A. Chapter 7080 requirements. <br />Divert surface drainage away or around the septic area. <br />All dimensions, quantities and elevation shown on plan are approximate. <br />I hereby certify that this site plan was prepared by me or <br />& Associates under my direca super 'ion. <br />Res.I / Bernie Miller Miller D.R. . M. P. C. A. License # 1921 <br />